Specifications

II Parameters
Base Specifications Parameters
II - 62
#1175 skip1 G31.1 skip condition
Designate the skip signal in multi-step skip G31.1.
The setting method is same as "#1173".
#1176 skip1f G31.2 skip speed
Set the skip feedrate in multi-step skip G31.1.
---Setting range---
1 to 999999 (mm/min)
#1177 skip2 G31.2 skip condition
Set the skip signal in multi-step skip G31.2.
The setting method is same as "#1173".
#1178 skip2f G31.2 skip speed
Set the skip signal in multi-step skip G31.2.
---Setting range---
1 to 999999 (mm/min)
#1179 skip3 G31.3 skip condition
Set the skip signal in multi-step skip G31.3
The setting method is same as "#1173".
#1180 skip3f G31.3 skip speed
Set the skip signal in multi-step skip G31.3.
---Setting range---
1 to 999999 (mm/min)
#1181 G96_ax Constant surface speed axis
Select the axis to be targeted for constant surface speed control.
0: Program setting will be disabled, and the axis will always be fixed to the 1st axis
1: 1st axis
2: 2nd axis
3: 3rd axis
:
8: 8th axis
However, when set to other than “0”, the priority will be on the program setting.
#1182 thr_F Thread cutting speed
Set the screw cut up speed when not using chamfering in the thread cutting cycle.
0: Cutting feed clamp feedrate
1 to 60000 mm/min: Setting feedrate
---Setting range---
0 to 60000 (mm/min)
#1183 clmp_M M code for clamp
Set the M code for C axis clamp in hole drilling cycle.
---Setting range---
0 to 99999999
#1184 clmp_D Dwelling time after outputting M code for unclamp
Set the dwell time after outputting the M code for C axis unclamp in hole drilling cycle.
---Setting range---
0.000 to 99999.999 (s)
#1185 spd_F1 F1 digit feedrate F1
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F1 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be
increased/decreased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)
#1186 spd_F2 F1 digit feedrate F2
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F2 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be
increased/decreased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)
#1187 spd_F3 F1 digit feedrate F3
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F3 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be
increased/decreased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)