Specifications

II Parameters
Base Specifications Parameters
II - 59
#1124 ofsfix Fix tool compensation No.
Select how to handle the compensation No. when the input key is pressed on the tool
compensation screen.
0: Increment the compensation No. by 1 (Same as general parameters)
1: # compensation No. does not change
When setting in sequence, “0” is handier. When changing and setting repeatedly while
adjusting one compensation value, “1” is handier
#1125 real_f Actual feedrate display
Select the feedrate display on the monitor screen.
0: Command speed
1: Actual travel feedrate
#1126 PB_G90 Playback G90
Select the method to command the playback travel amount in the playback editing.
0: Incremental value
1: Absolute value
#1127 DPRINT DPRINT alignment
Select the alignment for printing out with the DPRINT function.
0: No alignment, output s printed with left justification
1: Align the minimum digit and output
#1128 RstVCI Clear variables by resetting
Select how to handle the common variables when resetting.
0: Common variables won't change after resetting.
1: The following common variables will be cleared by resetting:
#100 to #149 when 100 sets of variables are provided.
#100 to #199 when 200 sets or more of variables are provided.
#1129 PwrVCl Clear variables by power-ON
Select how to handle the common variables when the power is turned ON.
0: The common variables are in the same state as before turning the power OFF.
1: The following common variables will be cleared when the power is turned ON:
#100 to #149 when 100 sets of variables are provided.
#100 to #199 when 200 sets or more of variables are provided.
#1130 set_t Display selected tool number
Select the tool command value display on the POSITION screen.
0: Display T-modal value of program command
1: Display Tool No. sent from PLC
#1132 brightness
Select the brightness of display unit.
1: High brightness (in bright state)
0: Medium brightness
-1: Low brightness (in dim state)
(Note) This setting is valid only for M700VW/M700VS/M70V/M70/E70 Series.
Set this to "0" for M700 series display as it has no brightness control function.
#1133 ofsmem
Not used. Set to "0".
#1134 LCDneg
Not used. Set to "0".
#1135 unt_nm Unit name
Set the unit name.
Set with 4 or less characters consisting of both alphabets and numbers.
If "0" is set, the unit name won't be displayed.
---Setting range---
4 or less characters consisting of both alphabets and numbers
#1136 optype
Not used. Set to "0".
#1137 Cntsel
Not used. Set to "0".
#1138 Pnosel
Not used. Set to "0".
#1139 edtype
Not used. Set to "0".
#1140 Mn100 M code number
Set the first number of M code that corresponds to the setup Nos. from 100 to 199.
---Setting range-