Specifications

II Parameters
Base Specifications Parameters
II - 58
#1112(PR) S_TRG Validate status trigger method
Select the enable conditions for the user macro interrupt signal (UIT).
0: Enable when interrupt signal (UIT) turns ON
1: Enable when interrupt signal (UIT) is ON
#1113(PR) INT_2 Validate interrupt method type 2
Select the performance after user macro interrupt signal (UIT) input.
0: Execute interrupt program without waiting for block being executed to end
1: Execute interrupt program after completing block being executed
#1114 mcrint Macro argument initialization
Select whether to clear statements other than specified arguments by macro call.
Also select whether to clear local variables by power-ON and resetting.
0: Clear the non-specified arguments by macro call.
1: Hold non-specified arguments by macro call
2: Hold non-specified arguments by macro call, and clear local variables by power-ON
and resetting
#1115 thwait Waiting for thread cutting
Set the queue number during screw thread cutting when chamfering is disabled.
---Setting range---
0 to 99 (Approx. 4 ms)
Standard setting value: 4
#1116 G30SLM Invalidate soft limit (manual operation)
Enable this function when disabling the soft limit check function at the second to fourth
reference position return.
0: Enable soft limit function
1: Disable soft limit function
#1117(PR) H_sens
Select the handle response mode during handle feed.
0: Standard
1: High-speed
#1118 mirr_A Select how to set up the length of tools on cutter tables (opposed tables)
(for L system only)
Select one of the following two methods:
- Set the current length of tools on each facing turret.
- Set a value, assuming that the tools on each facing turret are in the same direction as that
of those on the base turret.
0: Current length of the tools on each facing turret
1: Value, assuming that the tools on each facing turret are in the same direction as that
of those on the base turret
#1119 Tmiron Select the mirror image of each facing turret with T command (for L
system only)
Select whether to enable the mirror image of each facing turret with the T command.
0: Disable
1: Enable
#1120(PR) TofVal Change macro variable
Select whether to change the macro variable (tool offset) numbers for shape compensation
and wear compensation.
0: Not change (Conventional specification)
1: Change the shape and wear compensation variable numbers each for X, Z, and R
#1121 edlk_c Edit lock C
Select the edit lock for program Nos. 9000 to 9999 in memory.
0: Editing possible
1: Editing prohibited. The file cannot be opened.
(Note) If #1122 is set to 1 or 2, 1 will be set in #1121 when the power is
turned ON.
#1122(PR) pglk_c Program display lock C
Select whether to prohibit the program display and search for program Nos. 9000 to 9999 in
memory.
0: Program display and search is possible
1: Program display is impossible. Search is possible.
2: Program display and search is impossible
(Note) If #1122 is set to 1 or 2, 1 will be set in #1121 when the power is
turned ON.
#1123 origin Origin set prohibit
Select whether to use the origin set function.
0: Use
1: Not use