Specifications

II Parameters
Base Specifications Parameters
II - 56
#1086 G0lntp G00 non-interpolation
Select the G00 travel path type.
0: Move linearly toward the end point. (interpolation type)
1: Move to the end point of each axis at the rapid traverse feedrate for each axis. (non-
interpolation)
(Note) If this parameter is set to "1", neither of the following functions will be available: rapid
traverse constant inclination acceleration/deceleration and rapid traverse constant
inclination multi-step acceleration/deceleration.
#1087 G96_G0 Constant surface speed control by rapid traverse feed command
Select how to handle the surface speed for the G00 command when using the constant
surface speed control function.
0: Calculate the surface speed constantly even during G00 movement
1: Calculate the surface speed at the block end point in the G00 command
#1088 G30SL Disable G30 soft limit
Select how to handle the soft limit during G30 (2nd reference position return).
0: Enable
1: Disable
#1091 Mpoint Ignore middle point
Select how to handle the middle point during G28 and G30 reference position return.
0: Pass the middle point designated in the program and move to the reference position.
1: Ignore the middle point designated in the program and move straight to the reference
position.
#1092 Tchg _A Replace tools for additional axis
Select the movement of the additional axis at the tool change position return command.
0: The additional axis will not move
1: After the standard axis returns, the additional axis will also return to the tool change
position
#1093 Wmvfin Synchronization between part systems method
Select the timing of synchronization between part systems when using the multi-part
system.
When the travel command is found in the synchronization command (!, M) block:
0: Synchronize before executing travel command
1: Synchronize after executing travel command
#1094 Tl_SBK Select life count for single block (for L system only)
Select whether to count the data units to be used for single block operation when using the
tool life management II function (L system).
0: Not count
1: Count
#1095 T0tfof TF output (for L system only)
Select how to handle TF for T00 command.
0: TF will be output
1: TF wont be output
#1096(PR) T_Ltyp Tool life management type
Select the tool life management type.
1: Life management l
In this type, how long and how many times the program commanded tool is used are
accumulated to monitor the usage state.
2: Life management ll
This method is the same as tool life management I, but with the spare tool selection
function.
A spare tool is selected from a group of tool commands commanded in the program.
Tool compensation (tool length compensation and tool radius compensation) is
carried out for the selected tool.
3: Life management lll (for M system only)
The usage time or frequency of use which is designated by the program is
accumulated, and the tool usage state is monitored.
It is not managed by the group number.
(Note) When "3" is set for the L system, the Life management l is selected.
#1097 Tldigt Tool wear compensation number 1-digit command
Select the number of digits of the tool wear compensation No. in the T command.
0: The 2 high-order digits are the tool No., and the 2 low-order digits are the wear
compensation No.
1: The 3 high-order digits are the tool No., and the 1 low-order digit is the wear
compensation No.
This parameter will be fixed to “0” when tool life management II is selected.
#1098 Tlno. Tool length offset number
Select the number of digits of the tool length compensation No. in the T command.
0: The 2 or 3 high-order digits are the tool No.
The 2 or 1 low-order digits are the tool length compensation and wear compensation
Nos.
1: The 2 or 3 high-order digits are the tool No. and tool length compensation Nos.
The 2 or 1 low-order digits are the wear compensation No.