【#1037(PR)】 cmdtyp Command type
Set the G code list and compensation type for programs.
1 : List1(for M) Type I (one compensation amount for one compensation No.)
2 : List1(for M) Type II (shape and wear compensation amounts for one comp. No.)
3 : List2(for L) Type III (shape and wear compensation amounts for one comp. No.)
4 : List3(for L) Ditto
5 : List4(for special L) Ditto
6 : List5(for special L) Ditto
7 : List6(for special L) Ditto
8 : List7(for special L) Ditto
9 : List8(for M) M2 form at type Type I
(one compensation amount for one compensation No.)
10 : List8(for M) M2 form at type Type II
(shape and wear compensation amounts for one compensation No.)
There are some items in the specifications that can be used or cannot be used according to
the value set in this parameter.
The file structure may also change depending on the compensation data type.
(Note) When this parameter is changed, the file system will be changed after the power is
turned ON.
So always execute format.
The new format will be enabled after turning the power ON again.
Setting order
(1) cmdtyp changeover -> (2) Turn power ON again -> (3) Format -> (4) Turn power ON
again
【#1038】 plcsel Ladder selection
Not used. Set to "0".
【#1039(PR)】 spinno Number of spindles
Select the number of spindles.
0: No spindle
1 to 6: One to six spindles
(Note) The setting range differs according to the model.
【#1040(PR)】 M_inch Constant input (inch)
Select the unit system for setting and display regarding machine parameter and PLC
interface's position, length and speed.
0: Metric system
1: Inch system
【#1041(PR)】 l_inch Initial state (inch)
Select the unit system for the program travel amount when the power is turned ON or reset
and for position display.
0: Metric system
1: Inch system
(Note) The units of the following data are converted by "#1041 I_inch".
- Command unit at power ON and reset (Inch/metric command mode)
But under the following conditions, the unit will follow G20/G21 command modal
even at reset.
When reset modal is retained ("#1151 rstint"="0")
When G code group 06 reset modal is retained ("#1210 RstGmd/bit5" ON)
- Unit system for position display (counter, user parameter, tool, work offset)
- User parameter I/O unit
- Parameter unit of user parameters concerning length and speed
- Arc error parameter (#1084 RadErr)
【#1042(PR)】 pcinch PLC axis command (inch)
Select the unit system for the commands to the PLC axis.
0: Metric system
1: Inch system
【#1043】 lang Select language displayed
Select the display language.
0: English (Standard)
1: Japanese (Standard)
11: German (Option)
12: French (Option)
13: Italian (Option)
14: Spanish (Option)
15: Traditional Chinese (Option)
16: Korean (Option)
17: Portuguese (Option)
18: Dutch (Option)
19: Swedish (Option)
20: Hungarian (Option)
21: Polish (Option)
22: Simplified Chinese (Option)
23: Russian (Option)
24: Turkish (Option)
25: Czech (Option)
(Note) A language which can be displayed is different according to each series.