Specifications
II Parameters
User Parameters
II - 49
【#19008】 PRM coord rot type
Select the start point of the initial travel command after parameter coordinate rotation.
0: Calculate the end position, assuming that the start point rotates in accordance with
the coordinates rotation.
1: Calculate the end position using the current position on the local coordinate system
before rotating, without rotating the start point in accordance with the coordinates
rotation.
【#19401】 G33.n chamfer spd
Not used.
【#19405】 Rotary ax drawing
Specify this parameter to draw a path of C axis (rotary axis) according to its rotation in the
graphic trace and 2D graphic trace.
When "#1013 axname" is set to "C", the axis is handled as a rotary axis.
By setting this parameter to "C", a rotation path around the Z axis on actual workpiece can
be expressed.
When the Graphic check rotary axis drawing option or Graphic trace rotary axis drawing
option is disabled, this parameter is ignored.
C:Enable this function
0:Disable this function
(Setting is cleared when "0" is set)
【#19406】 Hob retract ON at alarm
Select whether to enable the retract at an alarm during hobbing.
0:Disable
1:Enable
【#19407】 Hob retract acceleration deceleration OFF
Select whether to disable the acceleration/deceleration of a retract.
0:Enable
1:Disable
【#19417】 Hole dec check 2
This is enabled when #1253 set25 bit2 is 1.
The operation at the hole bottom and the hole drilling stop position is as below.
0: Perform no deceleration check.
1: Perform command deceleration check.
2: Perform in-position check.
<Target fixed cycles>
Machining center: G81, G82, G83, G73
Lathe : G83, G87, G83.2
【#19425】 ManualB Std R1
Set a radius used as standard for the rotary axis speed.
When the setting value of #19425 is larger than that of "#19427 ManualB Std R2", #19425
setting will be used as surface speed control standard radius 2: #19427 setting will be used
as surface speed control standard radius 1.
---Setting range---
0 to 99999.999 (mm)
【#19426】 ManualB Std F1
This sets the rotary axis speed for surface speed control standard radius 1 (ManualB Std
R1).
When the setting value of #19426 is larger than that of "#19428 ManualB Std F2", #19426
setting will be used as surface speed control standard speed 2: #19427 setting will be used
as surface speed control standard speed 1.
---Setting range---
1 to 1000000 (°/min)
【#19427】 ManualB Std R2
Set a radius used as standard for the rotary axis speed.
When the same value is set as "#19425 ManualB Std R1", the surface speed control
standard speed 1 (ManualB Std F1) will be selected as the rotary axis speed if the radius is
less than that value. The surface speed control standard speed 2 (ManualB Std F2) is
selected if larger than the set value.
---Setting range---
0 to 99999.999 (mm)
【#19428】 ManualB Std F2
Set the rotary axis speed for surface speed control standard radius 2 (ManualB Std R2).
---Setting range---
1 to 1000000 (°/min)