Specifications

II Parameters
User Parameters
II - 39
#9610 LINK PARAM. 2
Bit 2: Specify the control code parity (even parity for the control code).
Select whether to add an even parity to the control code, in accordance with the I/O device
specifications.
0: Not add a parity bit to the control code
1: Add a parity bit to the control code
Bit 3: Parity V
Select whether to enable checking of parity V in one block at the input of the data.
0: Disable
1: Enable
#9611 Link PARAM. 3
Not used. Set to "0".
#9612 Link PARAM. 4
Not used. Set to “0”.
#9613 Link PARAM. 5
Not used. Set to “0”.
#9614 START CODE
Select the code used to command the first transfer of file data.
This parameter is used for a specific user. Normally set "0".
0: DC1 (11H)
1: BEL (07H)
#9615 CTRL. CODE OUT
bit 0: NAK output
Select whether to send the NAK code to the host if a communication error occurs in
computer link B.
0: Not output the NAK code
1: Output the NAK code.
bit 1: SYN output
Select whether to send the SYN code to the host if NC resetting or an emergency stop
occurs in computer link B.
0: Not output the SYN code.
1: Output the SYN code.
bit 3: DC3 output
Select whether to send the DC3 code to the host when the communication ends in
computer link B.
0: Not output the DC3 code.
1: Output the DC3 code.
#9616 CTRL. INTERVAL
Not used. Set to “0”.
#9617 WAIT TIME
Not used. Set to “0”.
#9618 PACKET LENGTH
Not used. Set to “0”.
#9619 BUFFER SIZE
Not used. Set to “0”.
#9620 START SIZE
Not used. Set to “0”.
#9621 DC1 OUT SIZE
Not used. Set to “0”.
#9622 POLLING TIMER
Not used. Set to “0”.
#9623 TRANS. WAIT TMR
Not used. Set to “0”.
#9624 RETRY COUNTER
Not used. Set to “0”.
#9701(PR) IP addr auto set
The IP address is automatically assigned from the server.
0: Manual setting
1: Automatic setting
(Note) When the automatic setting is selected, "#11005 PC IP address, PC Subnet, PC
Gateway" will be invalid.