Specifications
II Parameters
User Parameters
II - 38
【#9601】 BAUD RATE
Select the rate at which data is transferred.
0: 19200 (bps)
1: 9600
2: 4800
3: 2400
4: 1200
5: 600
6: 300
7: 110
8: 38400
【#9602】 STOP BIT
Select the stop bit length used in the start-stop system.
Refer to "#9603 PARITY EFFECTIVE". At the output of data, the number of characters is
always adjusted to for the parity check.
1: 1 (bit)
2: 1.5
3: 2
【#9603】 PARITY EFFECTIVE
Select whether to add the parity bit to the data.
The parameter is set when using a parity bit separately from the data bit.
Set this parameter according to the specifications of input/output device.
0: Not add a parity bit at the input/output
1: Add a parity bit at the input/output
【#9604】 EVEN PARITY
Select odd or even when parity is added to the data. This parameter is ignored when no
parity is added.
0: Odd parity
1: Even parity
【#9605】 CHR. LENGTH
Select the length of the data bit.
Refer to "#9603 PARITY EFFECTIVE".
0: 5 (bit)
1: 6
2: 7 (NC connection not supported)
3: 8
【#9606】 HAND SHAKE
Select the transmission control method.
"3" (DC code method) should be set for computer link B.
0: No control
1: RTS/CTS method
2: No handshaking
3: DC code method
【#9607】 TIME-OUT SET
Set the time-out time at which an interruption of data transfer during data input/output
should be detected.
"0" means infinite time-out.
---Setting range---
0 to 999 (1/10s)
【#9608】 DATA CODE
Set the code to be used for the data description.
Refer to "#9603 PARITY EFFECTIVE".
0: ASCII code
1: ISO code
【#9609】 LINK PARAM. 1
bit1: DC1 output after NAK or SYN
Select whether to output the DC1 code after the NAK or SYN code is output.
0: Not output the DC1 code.
1: Output the DC1 code.
bit7: Enable/disable resetting
Select whether to enable the resetting in the computer link.
0: Enable
1: Disable
1character
Stop bit
Parity bitData bit
Start bit
ON
OFF
b1 b2 b3 b4 b5 b6 bn