Specifications

II Parameters
User Parameters
II - 37
#9520 DEV4 OUT BUFFER
Select the buffer size of the output data which is output to output device using NC side serial
port.
If the output device has a transmission error (overrun error), decrease the buffer size with
this parameter.
If the buffer size is decreased, output time will prolong according to the size.
0: 250 bytes (default)
1: 1 byte
2: 4 byte
3: 8 byte
4: 16 byte
5: 64 byte
#9521 DEV4 EIA CODE [
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code " [ ".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9522 DEV4 EIA CODE ]
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code " ] ".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9523 DEV4 EIA CODE #
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "#".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9524 DEV4 EIA CODE *
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "*".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9525 DEV4 EIA CODE =
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "=".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9526 DEV4 EIA CODE :
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code " : ".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9527 DEV4 EIA CODE $
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "$".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9528 DEV4 EIA CODE !
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "!".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)