Specifications
II Parameters
User Parameters
II - 35
【#9425】 DEV3 EIA CODE =
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "=".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9426】 DEV3 EIA CODE :
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code " : ".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9427】 DEV3 EIA CODE $
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "$".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9428】 DEV3 EIA CODE !
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "!".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9501】 DEV4 DEVICE NAME
Set the device name corresponding to the device No.
Set a simple name for quick identification.
---Setting range---
Use alphabet characters, numerals and symbols to set a name within 3 characters.
【#9502】 DEV4 BAUD RATE
Select the serial communication speed.
0: 19200 (bps)
1: 9600
2: 4800
3: 2400
4: 1200
5: 600
6: 300
7: 110
【#9503】 DEV4 STOP BIT
Select the stop bit length used in the start-stop system.
Refer to "#9504 DEV4 PARITY CHECK". At the output of data, the number of characters is
always adjusted to for the parity check.
1: 1 (bit)
2: 1.5
3: 2
【#9504】 DEV4 PARITY CHECK
Select whether to add a parity check bit to the data.
Set this parameter in accordance with the I/O device specifications.
0: Not add a parity bit in I/O mode
1: Add a parity bit in I/O mode
【#9505】 DEV4 EVEN PARITY
Select whether even or odd parity will be used when parity is used. This parameter is
ignored when no parity is added.
0: Odd parity
1: Even parity
【#9506】 DEV4 CHR. LENGTH
Select the length of the data bit.
Refer to "#9504 DEV4 PARITY CHECK".
0: 5 (bit)
1: 6
2: 7 (NC connection not supported)
3: 8
1character
Stop bit
Parity bitData bit
Start bit
ON
OFF
b1 b2 b3 b4 b5 b6 bn