Specifications

II Parameters
User Parameters
II - 34
#9414 DEV3 FEED CHR.
Set the length of the tape feed to be output at the start and end of the data during tape
output.
---Setting range---
0 to 999 (characters)
#9415 DEV3 PARITY V
Select whether to perform the parity check for the number of characters in a block at the
input of data.
At the output of data, the number of characters is always adjusted to for the parity check.
0: Not perform parity V check
1: Perform parity V check
#9416 DEV3 TIME-OUT (sec)
Set the time out time to detect an interruption in communication.
Time out check will not be executed when set to "0".
---Setting range---
0 to 30 (s)
#9417 DEV3 DR OFF
Select whether to enable the DR data check in data I/O mode.
0: Enable
1: Disable
#9418 DEV3 DATA ASCII
Select the code of the output data.
0: ISO/EIA code (Depends on whether #9113, #9213, #9313, #9413 or #9513 EIA
output parameter is set up.)
1: ASCII code
#9419 DEV3 INPUT TYPE
Select the mode for input (verification).
0: Standard input (Data from the very first EOB is handled as significant information.)
1: EOBs following the first EOB of the input data are skipped until data other than EOB
is input.
#9420 DEV3 OUT BUFFER
Select the buffer size of the output data which is output to output device using NC side serial
port.
If the output device has a data receiving error (overrun error), decrease the buffer size with
this parameter.
If the buffer size is decreased, output time will prolong according to the size.
0: 250 bytes (default)
1: 1 byte
2: 4 bytes
3: 8 bytes
4: 16 bytes
5: 64 bytes
#9421 DEV3 EIA CODE [
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code " [ ".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9422 DEV3 EIA CODE ]
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code " ] ".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9423 DEV3 EIA CODE #
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "#".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9424 DEV3 EIA CODE *
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "*".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)