Specifications

II Parameters
User Parameters
II - 33
#9402 DEV3 BAUD RATE
Select the serial communication speed.
0: 19200 (bps)
1: 9600
2: 4800
3: 2400
4: 1200
5: 600
6: 300
7: 110
#9403 DEV3 STOP BIT
Select the stop bit length used in the start-stop system.
Refer to "#9404 DEV3 PARITY CHECK". At the output of data, the number of characters is
always adjusted to for the parity check.
1: 1 (bit)
2: 1.5
3: 2
#9404 DEV3 PARITY CHECK
Select whether to add a parity check bit to the data.
Set this parameter in accordance with the I/O device specifications.
0: Not add a parity bit in I/O mode
1: Add a parity bit in I/O mode
#9405 DEV3 EVEN PARITY
Select whether even or odd parity will be used when parity is used. This parameter is
ignored when no parity is added.
0: Odd parity
1: Even parity
#9406 DEV3 CHR. LENGTH
Select the length of the data bit.
Refer to "#9404 DEV3 PARITY CHECK".
0: 5 (bit)
1: 6
2: 7 (NC connection not supported)
3: 8
#9407 DEV3 TERMINATR TYP
Select the code to terminate data reading.
0, 3: EOR
1, 2: EOB or EOR
[When M700/700VW display side serial port is selected]
0: No terminator
1: EOR
2: EOB
3: EOB or EOR
#9408 DEV3 HAND SHAKE
Select the transmission control method.
No handshaking will be used when a value except 1 to 3 is set.
1: RTS/CTS method
2: No handshaking
3: DC code method
#9409 DEV3 DC CODE PRTY
Select the DC code type when the DC code method is selected.
0: Not add parity to DC code (DC3 = 13H)
1: Add parity to DC code (DC3 = 93H)
#9411 DEV3 DC2/4 OUTPUT
Select the DC code handling when outputting data to the output device.
DC2 / DC4
0: None / None
1: Yes / None
2: None / Yes
3: Yes / Yes
#9412 DEV3 CR OUTPUT
Select whether to add the (CR) code just before the EOB (L/F) code during output.
0: Not add
1: Add
#9413 DEV3 EIA OUTPUT
Select ISO or EIA code for data output.
In data input mode, the ISO and EIA codes are identified automatically.
0: ISO code output
1: EIA code output
1character
Stop bit
Parity bitData bit
Start bit
ON
OFF
b1 b2 b3 b4 b5 b6 bn