Specifications
I Alarms
Operation Errors (M)
I - 5
M01 Restart switch ON 0111
Details
Restart switch has been turned ON and manual mode has been selected before the restart
search is completed.
Remedy
- Search the block to restart.
- Turn the restart switch OFF.
M01 Program check mode 0112
Details
The automatic start button was pressed during program check or in program check mode.
Remedy
- Press the reset button to cancel the program check mode.
M01 Auto start in buffer correct 0113
Details
The automatic start button was pressed during buffer correction.
Remedy
- Press the automatic start button after the buffer correction is completed.
M01 In reset process 0115
Details
The automatic start button was pressed during resetting or tape rewinding.
Remedy
- When rewinding the tape, wait for the winding to end, or press the reset button to stop the
winding, and then press the automatic start button.
- During resetting, wait for the resetting to end, and then press the automatic start button.
M01 Playback not possible 0117
Details
The playback switch was turned ON during editing.
Remedy
- Cancel the editing by pressing the input or previous screen key before turning ON the play-
back switch.
M01 Turn stop in normal line cntrl 0118
Details
The turning angle at the block joint exceeded the limit during normal line control.
In normal line control type I:
"#1523 C_feed (Normal line control axis turning speed)" has not been set.
In normal line control type II:
When turning in the inside of the arc, the set value for "#8041 C-rot. R" is larger than the arc
radius.
Remedy
- Correct the program.
- Correct the "#1523 C_feed (Normal line control axis turning speed)" setting.
- Correct the "#8041 C rot. R" setting.
M01 Reverse run impossible 0119
Details
Either of the following conditions occurred:
- there is no block to run backward.
- eight blocks has been continued without any travel command.
Remedy
- Execute forward run to clear the alarm.
- Reset to clear the alarm.
M01 In synchronous correction mode 0120
Details
The synchronous correction mode switch was pressed in non-handle mode.
Remedy
- Select the handle or manual arbitrary feed mode.
- Turn OFF the correction mode switch.
M01 No synchronous control option 0121
Details
The synchronous control operation method was set (with R2589) while no synchronous con-
trol option was provided.
Remedy
- Set "0" for "synchronous control operation method".
M01 Computer link B not possible 0123
Details
Cycle start was attempted before resetting was completed.
Computer link B operation was attempted at the 2nd or further part system in a multi-part sys-
tem.
Remedy
- Perform the cycle start after resetting has been completed.
- Set "#8109 HOST LINK" to "0" and then set to "1" before performing the cycle start.
- Computer link B operation cannot be performed at the 2nd or further part system in a multi-
part system.
M01 X/Z axes simultaneous prohibit 0124
Details
The basic axis corresponding to the inclined axis was started simultaneously in the manual
mode while the inclined axis control was valid.
Remedy
- Turn the inclined axis and basic axis start OFF for both axes. (This is also applied for man-
ual/automatic simultaneous start.)
- Disable the basic axis compensation, or command it to axes one by one.
M01 Rapid override zero 0125
Details
The RAPID TRAVERSE OVERRIDE switch on the machine operation panel is set to "0".
Remedy
- Set the RAPID TRAVERSE OVERRIDE switch to a value other than "0" to clear the error.
- If the RAPID TRAVERSE OVERRIDE switch has been set to a value other than "0", check
for any short circuit in the signal line.
- Correct the sequence program.