Specifications

II Parameters
User Parameters
II - 32
#9320 DEV2 OUT BUFFER
Select the buffer size of the output data which is output to output device using NC side serial
port.
If the output device has a transmission error (overrun error), decrease the buffer size with
this parameter.
If the buffer size is decreased, output time will prolong according to the size.
0: 250 bytes (default)
1: 1 byte
2: 4 byte
3: 8 byte
4: 16 byte
5: 64 byte
#9321 DEV2 EIA CODE [
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code " [ ".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9322 DEV2 EIA CODE ]
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code " ] ".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9323 DEV2 EIA CODE #
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "#".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9324 DEV2 EIA CODE *
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "*".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9325 DEV2 EIA CODE =
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "=".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9326 DEV2 EIA CODE :
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code " : ".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9327 DEV2 EIA CODE $
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "$".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9328 DEV2 EIA CODE !
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "!".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
#9401 DEV3 DEVICE NAME
Set the device name corresponding to the device No.
Set a simple name for quick identification.
---Setting range---
Use alphabet characters, numerals and symbols to set a name within 3 characters.