Specifications
II Parameters
User Parameters
II - 32
【#9320】 DEV2 OUT BUFFER
Select the buffer size of the output data which is output to output device using NC side serial
port.
If the output device has a transmission error (overrun error), decrease the buffer size with
this parameter.
If the buffer size is decreased, output time will prolong according to the size.
0: 250 bytes (default)
1: 1 byte
2: 4 byte
3: 8 byte
4: 16 byte
5: 64 byte
【#9321】 DEV2 EIA CODE [
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code " [ ".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9322】 DEV2 EIA CODE ]
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code " ] ".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9323】 DEV2 EIA CODE #
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "#".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9324】 DEV2 EIA CODE *
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "*".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9325】 DEV2 EIA CODE =
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "=".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9326】 DEV2 EIA CODE :
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code " : ".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9327】 DEV2 EIA CODE $
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "$".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9328】 DEV2 EIA CODE !
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the
special code "!".
When output with EIA code, data can be output using the alternate code in which the
special ISO code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9401】 DEV3 DEVICE NAME
Set the device name corresponding to the device No.
Set a simple name for quick identification.
---Setting range---
Use alphabet characters, numerals and symbols to set a name within 3 characters.