Specifications
II Parameters
User Parameters
II - 23
【#8944(PR)】 $3 color
Set the color to be shown on the top-left of screen for the 3rd part system. This enables
switching the color patterns for each part system. When set to the values 1 to 4, the part
system name is shown in the form of button image.
Note) Enabled when #8942 ($1 color) is set to the values 1 to 4.
1: Purple (default)
2: Pink
3: Light blue
4: Orange
【#8945(PR)】 $4 color
Set the color to be shown on the top-left of screen for the 4th part system. This enables
switching the color patterns for each part system. When set to the values 1 to 4, the part
system name is shown in the form of button image.
Note) Enabled when #8942 ($1 color) is set to the values 1 to 4.
1: Purple (default)
2: Pink
3: Light blue
4: Orange
【#8951】 No Tab counter sw.
Disable Tab key to change the counter type.
0: Enable Tab key to change counter typ
(The value of #8905 also changes)
1: Disable Tab key to change counter type
【#8952】 Edit-win $ switch
Select whether to enable switching of program displayed in the edit window on Monitor
screen according to the displayed part system when part system switch is performed.
0: Not switch
1: Switch
【#8953】 2$ disp switch typ
Select how to switch the part system to display when the 2-part system simultaneous
display is enabled.
0: Switch by incrementing the No. of part system to display by one.
1: Switch by skipping the system displayed in the non-active area. When a window is
being popped up, however, this skip is not performed and the system is switched
by incrementing the No. by one.
【#8954】 Initial type
Select the default setting of the coordinate axis direction designation method to be
displayed on the [Surface detail] screen of R-Navi.
0,1: Point (+) on the axis
2: Latitude/Longitude
3: Latitude/Projection angle
4: Start point/End point
5: Index angle
【#8955】 Init axis pair
Select the default coordinate axis combination to be displayed on the [Surface detail] screen
of R-Navi.
0,1: Z/X
2: Z/Y
3: X/Y
【#8956(PR)】 User key type
Select the definition type of the user-defined keys.
There are two user-defined keys.
Type 1:
It is the same as the conventional specification. A line feed between "[]" is not dealt as
";".
It is dealt as an upper case/lower case letter depending on the CapsLock status.
A symbolic character may be converted into a specific character.
Type 2:
A line break inside square brackets "[]" is dealt as ";".
Regardless of the CapsLock status, the defined character is input.
A symbolic character is also input as defined.
0 : Type 1 (Conventional specification)
1 : Type 2
(Note) This parameter is valid for M700VW series.
【#8957(PR)】 T meas (L)-Simple
Select the operation mode of the manual tool length measurement 1 for L system.
0: Normal operation mode (Conventional specification)
Select an axis to measure using the cursor position.
1: Simple operation mode
Select an axis to measure using an axis address key or menu.
More than one axis can be selected.
【#9001】 DATA IN PORT
Select the port for inputting the data such as machine program and parameters.
1: ch1
2: ch2