Specifications
43
CONNECTIONS
PRINTING
PRECAUTIONS FEATURES
PREPARATION
OTHERS
TROUBLE-
SHOOTING
ADJUSTMENTS
V SYNC
BUSY OUTPUT
Image meorizing
a
a=approx.820 µsec.
V SYNC
BUSY OUTPUT
Image memorizing
SYNCHRONOUS SETTING FOR MEMORY
STROBE : 1V, BUSY LEVEL : HIGH in REMOTE SET of SERVICE MENU
STROBE : 2V, BUSY LEVEL : HIGH in REMOTE SET of SERVICE MENU
The numbers in the above figures are just references. The timing may be different
according to the setting.
REMOTE SET
BUSY LEVEL LOW/HIGH
BUSY1,2 SELECT
PRINTING
OFF/1/2/1&2
MECHA ERR
OFF/1/2/1&2
MEDIA ERR
OFF/1/2/1&2
MEMORY STOP
OFF/1/2/1&2
STROBE 1V OFF/1/2/1&2
STROBE 2V OFF/1/2/1&2
REMAINING
OFF/1/2/1&2
PREVIOUS ERROR Error display
This function displays the most recent type of error.
PREVIOUS ERROR
NO ERROR
NO ERROR
NO ERROR
REMOTE SET Remote signal setting display
BUSY LEVEL Selects the level of BUSY signal from the remote terminals 1 and 2
on the rear panel.
LOW The VCP cannot accept the remote input signal when the signal is
“LOW”.
HIGH The VCP cannot accept the remote input signal when the signal is
“HIGH”.
• The default setting is “HIGH”.
BUSY 1,2 SELECT Selects when the BUSY signal is outputted from the remote
terminals 1 and 2 on the rear panel.
PRINTING Outputs BUSY signal during printing.
MECHA ERR Outputs BUSY signal when a mechanical error occurs in this unit or
IC chip is not installed. BUSY signal is also outputted when the
printing mechanism is pulled out or the menu is displayed on the
monitor.
MEDIA ERR Outputs BUSY signal when an error for paper or ink sheet occurs.
MEMORY STOP Outputs BUSY signal when MEMORY button is not functioning.
STROBE 1V After outputting BUSY signal, memory is taken in by waiting to 1
vertical period.
STROBE 2V After outputting BUSY signal, memory is taken in by waiting to 2
vertical periods.
REMAINING Outputs BUSY signal when the remains of ink sheet becomes the
value set in REMAINING Q’ty.
• When either STROBE 1V or STROBE 2V is set to OFF, the other is available for
setting.