31
CONNECTIONS
PRINTING
PRECAUTIONS FEATURES
PREPARATION
OTHERS
TROUBLE-
SHOOTING
ADJUSTMENTS
AFC(Automatic frequency control)
The image distortion on the top may occur when the VCR
image is special input such as in pause, field-by-field
playback, or FF playback mode. Also, the image is not
printed correctly because of a weak TV signal. In this case,
set the AFC function to “ON.”
• The image distortion on the top may occur by the special signals when AFC is set to
“ON”. In this case, set it to “OFF.”
OFF AFC is invalid
ON AFC is available
AGC(Automatic gain control)
This function is to automatically adjust a dark picture in
brightness and prints with sharp contrast. Peak level of an
input signal is detected and signals width is standardized to
the appropriate value.
OFF AGC is invalid
ON AGC is available
OUTPUT Output signal setting display
MONI R-SUB Adjusts red-subcontrast on the monitor. Red is added with and
blue is added with .
MONI B-SUB Adjusts blue-subcontrast on the monitor. Blue is added with and
yellow is added with .
KEY SET Button function setting display
KEY LOCK Makes the function on the remote control unit buttons invalid.
OFF All buttons on the remote control unit are available.
ON The function on the remote control unit buttons, except MEMORY,
PRINT, MONITOR and MEMORY PAGE are not available.
When pressing MENU button, KEY SET menu is displayed.
When pressing MENU button, only selecting OFF/ON of KEY
LOCK is available.
MEM&PRN (Memory and Print)
When pressing MEMORY button, the image is automatically printed
after the image is stored in the memory. When selecting 4D at
IMAGES, printing will be done after the last image is stored in
memory.
OFF MEMORY button functions individually. The image is memorized
without printing.
ON Automatically prints after memorizing.
R1 When a signal inputted through a memory key (pin No. 2) of the
remote terminal on the rear panel is switched to “low” level from
“high” for the first time, a memory image is displayed. Then at the
second time, a source image is displayed without printing the
memory image.
R2 On the KEEP MONI OFF status, when a signal inputted through a
memory key (pin No. 2) of the remote terminal is switched to “low”
level from “high” for the first time, a memory image is displayed.
Then at the second time, a source image is displayed and the
memory image is printed.
KEY SET
KEY LOCK OFF/ON
MEM&PRN OFF/ON/R1/R2
MEM&STOP OFF/PAGE
MEM&MONI OFF/ON
KEEP MONI OFF/ON
AUTO CLEAR OFF/AFTER PRN
CLEAR KEY PAGE/ALL
OUTPUT
MONI R-SUB 0
MONI B-SUB 0
Source
Memory
source
Memorizing
Not printing
Display
Remote terminal input
source
Memory source
Memorizing Printing
Display
Remote terminal input
R1