Instruction manual

30
ADJUSTMENTS & SETTINGS (SERVICE MENU)
ANALOG COLOR ADJ
INPUT COLOR/B&W
BRT : 0
CONT : 0
R-SUB : 0 C R
G-SUB : 0 M G
B-SUB : 0 Y B
COLOR : 0
CENTER [ ]
CANCEL [ ]
INPUT
FIELD NOR/REV
AFC OFF/ON
AGC OFF/ON
LAYOUT2
SEPARATE OFF/ON
MARGIN CUT OFF/ON
Gray part is
cut when
MARGIN CUT
is ON.
SELECT Is displayed when selecting EACH in COLOR.
R Adjusting gamma level for red.
G Adjusting gamma level for green.
B Adjusting gamma level for blue.
Changing gamma curve:
Use the , buttons on the remote control unit to select the Hi/Mid/Low gamma
point to set.
Also use , buttons to input setting level.
NOTE
It takes time to set the gamma value by CPU. Wait until the normal display is
shown after pressing SET button.
LAYOUT2 Layout setting display 2
SEPARATE Selects whether a white frame is added to each print or not.
OFF Prints without white frame. ( A white frame appears according to the settings
of LAYOUT)
ON Prints with white frame.
MARGIN CUT Cuts the margin of the printed paper.
This function is very convenient to stick the printed image on the card. The figure
shows S size print paper setting.
OFF Margin is not cut.
ON Margin is cut.
ANALOG COLOR ADJ Analog color adjustment display
This menu is used to adjust the image of analog input signal before storing in the
memory.
INPUT Selects black and white image or color image.
B&W The image on the display becomes black and white.
COLOR Color image
BRT (Bright) Adjusts the brightness of the printing image.
CONT (Contrast) Adjusts the contrast of the printing image.
R-SUB Adjusts red-subcontrast of the printing image. Red is added with
and blue is added with .
G-SUB Adjusts green-subcontrast of the printing image. Green is added
with and pink is added with .
B-SUB Adjusts blue-subcontrast of the printing image. Blue is added
with and yellow is added with .
COLOR Adjusts density of the printing image. The color of the image
gets deeper with and lighter with .
CENTER Initializes each setting. When pressing , the values of BRT,
CONT, R-SUB, G-SUB, B-SUB and COLOR will be reset to 0.
INPUT Input signal setting display
Set this menu before memorizing image.
FIELD The odd and even field lines will be reversed depending on the input
interlaced signal. Printing image is not clear so that the odd and even
field lines may be reversed depending on the input interlaced signal. In
this case, FIELD is set to REV. (The image disorder cannot be seen
in monitor display.)
NOR(Normal) Not reversed
REV(Reverse) Reverse the even and odd numbers of FIELD