EXTERNAL REMOTE TERMINAL 1
The image can be stored in memory by sending the remote signal through the external
remote terminal on the rear panel. When the MEM&PRN(MEMORY & PRINT) function
is set to ON, the image will be printed after being stored in memory.
Make out the necessary circuit to use this function by referring to the following.
EXTERNAL REMOTE TERMINAL SIGNAL ALLOCATION (STEREO
JACK)
Pin No. Function Description
Ground Earth
MEMORY Memory : When the signal becomes LOW from HIGH, the
image is stored in memory. (When the signal has
been LOW for 60ms or more, the image is stored
in memory.) See page 31.
BUSY1 Refer to the BUSY LEVEL setting of REMOTE SET in SERVICE
MENU. See page 32.
When the signal from BUSY terminal is received with TTL level, keep the following.
| I
OL
| = 2mA or less, | I
OH
| = 1mA or less
| I
OL
| means the current flowing into the unit at Low output, | I
OH
| means the
current flowing out of the unit at High output.
Circuit inside and pin No.
Plug pin No.
PRINTING (SPECIAL)
EXTERNAL REMOTE TERMINAL 2
The image can be stored in memory and printed by sending the remote signal through
the external remote terminal on the rear panel.
Make out the necessary circuit to use this function by referring to the following.
EXTERNAL REMOTE TERMINAL SIGNAL ALLOCATION (MINI
DIN8PIN)
Pin No. Function Description
Ground Earth
MEMORY Memory : When the signal becomes LOW from HIGH, the
image is stored in memory. (When the signal has
been LOW for 60ms or more, the image is stored
in memory.) See page 31.
BUSY2 Refer to the BUSY LEVEL setting of REMOTE SET in
SERVICE MENU. See page 32.
BUSY1 Refer to the BUSY LEVEL setting of REMOTE SET in
SERVICE MENU. See page 32.
PRINT When the signal becomes LOW from HIGH, the image is
stored in memory. (When the signal has been LOW for 60ms
or more, the image is stored in memory.
REMOTE The same functions as the supplied remote control unit can
be controlled.
Unused
DC3V Power supply for the remote control unit DC 1mA Max.
When the signal from BUSY terminal is received with TTL level, keep the following.
| I
OL
| = 2mA or less, | I
OH
| = 1mA or less
| I
OL
| means the current flowing into the unit at Low output, | I
OH
| means the
current flowing out of the unit at High output.
22k
22k
10k
100
DTC124EK
DC5V
1k
74LVC125
10k
100
DC5V
To VCP
To VCP
From VCP
To VCP
Circuit inside the VCP
MEMORY
BUSY2
PRINT
REMOTE
BUSY1
74LVC125
10k
100
DC5V
TTL level
TTL level
56k
Pin No.
22k
22k
10k
100
DTC124EK
DC5V
22k
10k
100
DTC124EK
DC5V
22k
To VCP
From VCP
Circuit inside the VCP
MEMORY
BUSY
DMC2838