Technical data
32
MITSUBISHI ELECTRIC
OPTIONS AND PERIPHERAL EQUIPMENT
4
왎
Noise Filters
U1
V1
W1
왎 Brake Resistors
Resistor Servo amplifier
Power
capacity
[W]
Resistance
(Ω)
Weight
[kg]
Dimensions
(WxHxD)
Order
number
MR-RFH75-40
MR-J3-10A/B/T – MR-J3-60A/B/T,
MR-J3-70A/B/T and MR-J3-100A/B/T
150 40 0.16 36 x 27 x 90 137279
MR-RFH220-40 MR-J3-70A/B/T and MR-J3-100A/B/T 400 40 0.42 36 x 27 x 200 137278
MR-RFH400-13
MR-J3-200A/B/T, MR-J3-350A/B/T
and MR-J3-500A/B/T
600 13 0.73 36 x 27 x 320 137277
MR-RFH400-6.7 MR-J3-700A/B/T 600 6.7 0.73 36 x 27 x 320 137275
MR-PWR-T-400-120 MR-J3-60A4/B4 and MR-J3-100A4/B4 400 120 0.4 36 x 27 x 200 154746
MR-PWR-T-600-47 MR-J3-200A4/B4 and MR-J3-350A4/B4 600 47 0.64 36 x 27 x 320 154751
MR-PWR-T-600-26 MR-J3-500A4/B4 and MR-J3-700A4/B4 600 26 0.64 36 x 27 x 320 154752
Filter
햲
Servo amplifier
Power
loss [W]
Rated
current [A]
Leakage
햳
current [mA]
Weight
[kg]
Order
number
MF-2F230-006.230MFa
MR-J3-10A/B/T – MR-J3-60A/B/T 10 6 < 26 0.45 189332
MF-2F230-006.230MFb
MR-J3-70A/B/T 10 6 < 26 0.45 189331
MF-3F480-010.230MF3
MR-J3-100A/B/T 9 10 < 7 1.0 203853
MF-3F480-010.233MF
MR-J3-60A4/B4, MR-J3-100A4/B4 9 10 < 7 1.0 208775
MF-3F480-015.230MF3
MR-J3-200A/B/T and MR-J3-200A4/B4 12 15 < 4
햳
1.5 203463
MF-3F480-015.233MF
MR-J3-350A4/B4 16 15 < 20 2.0 208776
MF-3F480-025.230MF3
햴
MR-J3-350A/B/T, MR-J3-500A4/B4/T
and MR-J3-700A4/B4
20 25 < 4 3.0 203854
MF-3F480-050.230MF3
MR-J3-500A/B/T and MR-J3-700A/B/T 40 50 < 4
햳
4.0 203855
햲
All filters can provide conformity with the limits for environment 1, restricted distribution up to 50 m or environment 1, unrestricted
distibution up to 20 m.
햳
At normal operation: voltage difference between 2 phases < 3 % / at fault occurrence (value in brackets) : 2 dead phases (worst case)
햴
No foot print filter
For complying with the EMC directives of
the European Community regarding
the electromagnetic compatibility, the
servo amplifiers have to be equipped
with a noise filter across the input circuit.
Additionally it has to be installed and
wired according to the EMC directives.
The filter units are designed to reduce
mains conducted RFI emissions to meet
the European standard EN 61800-3.
More details are enclosed in the
installation sheet of the MR-J3 filters.
If the regenerative power exceeds the
power of the built-in resistor, the following
listed optional brake resistors can be used.
/// NOISE FILTERS AND BRAKE RESISTORS/// NOISE FILTERS AND BRAKE RESISTORS
32
MR-J3-Super 2008 UK-neu.prn
MR-J3-Super 2008 UK
Montag, 21. April 2008 13:34:18
Farbprofil: Deaktiviert
Komposit Standardbildschirm