Technical data
22
MITSUBISHI ELECTRIC
3
SERVO AMPLIFIERS
L1
L2
L3
N
P1
P2
P
C
D
L11
L21
U
V
W
CN5CN6CN3
CN1
LCN2CN2CN4
CHARG
WARNING
M
R-J3-A
OPEN
5N
POWER
F
P
R
P
C
L
R
E
R
R
S
T
O
P
D
O
G
P
G
O
2N
-1PG
FX
POWER
READY
ERROR
CPU-E
A
U
TO
MANU
START
STOP
ZRN
FWD
RVS
DOG
LSF
LSR
X0
X1
X2
X3
Y0
Y1
Y2
Y3
Y4
Y5
SVRDY
SVEND
PG0FP
FP
RP
CLR
MITSUBISHI
MELSECFX
2N
-10GM
PLC
I/O
MOTOR
EXT
MITSUBISHI
OFF
ON
NO-FUSE BREAKER
NF125-SGW
In A
125
Ir 80-125A
MODEL
POLE
Ui690V
Cat.A
PUSHTO TRIP
Uimp8kV
3P
IEC60947-2
JISC 8201-2
Ue
690VAC
525VAC
500VAC
440VAC
380/415VAC
230VAC
300VAC
EN60947-2
40°C
Icu/Ics
8/8kA
22/22kA
30/30kA
36/36kA
36/36kA
85/85kA
20/20kA
MITSUBISHIELECTRIC
PAL
70%
50/60Hz
T
Ts
TL
Ii
Is
Ir
Ip
Ii(X100A)
Ir(A)
TL(S)
IS(xIr)
TS(S)
Ip(xIr)
63
100
100
12
2
2.5
10
.06
.07
.10
.3
4
6
8
10
12
14
.1
.2
8
7
6
5
4
80
3.5
3
60
80
OVER
MODEL
RE100 In 100A
OPEN
MELSEC
QD70P8
RUN
ERR.
AX5
AX6
AX7
AX8
AX1
AX2
AX3
AX4
CON1
CON2
A complete overview with detailed specifi
-
cations on all cables and accessories can
be found in the next chapter.
왎
MR-J3-A Servo Amplifier Connections with Peripheral Equipment
/// MR-J3-A SERVO AMPLIFIER PERIPHERALS
Power supply
No-fuse
circuit
breaker
(NFB)
Magnetic
contactor
(MC)
Powerfactorimprovement
reactor FR-BEL (optional)
Display panel (behind the cover)
Displays monitoring data, parameters and alarms.
Setting section (behind the cover)
Parameter settings and monitoring etc. can be exe-
cuted with push buttons.
USB communication via CN5
Monitoring, batch parameter entry and saving, graph
display and test operation can be performed with
MR-Configurator (setup software) when connecting
to user’s personal computer. Optional USB cable
(MR-J3USBCBL3M) is necessary.
Analog monitor output via CN6
The speed or torque’s analog signal is output
(2 channel).
RS232 communication via CN3
A GOT operator panel can be connected. (Note )
Junction terminal block (option)
All signals can be received easily at this terminal block
without connecting the signals to CN1.
Positioning controllers
MR-J3-A can be connected to a Mitsubishi controller or
any pulse train output controller.
Control signal (for operation panel)
Connected to the programmable controllers I/O port like
FX1S, FX1N, FX2N, FX3U or the machine's operation panel.
Battery (option)
The battery (MR-J3BAT) is required when the servo
system is in absolute mode. Not required when the
servo system is in incremental mode.
Optional
regene-
ration
unit can
be con
nected
here
Encoder cable (option)
Charge
lamp
Servo amplifier
MR-J3-A
Servo motor
Power supply
3~, 200–230 V AC
1~, 230 V AC for servo drives ≤ 750 W
3~, 400 V AC for servo drives ≥ 600 W (A4)
No-fuse circuit breaker (NFB)
Used to protect the power supply line.
Magnetic contactor (MC)
Used to turn OFF the power of the servo
amplifier.
Regeneration unit (option)
This unit can be installed in situations
involving frequent regeneration and large
load inertia moments. For more details
refer to the MR-J3-A users manual.
Charge lamp
Lights up when the main power supply is
on. Power lines should not be plugged
or unplugged when this lamp is on.
RS422 Communication
A personal computer can be connected
using a RS-422/RS-232C converter and a
conversion cable.
FX2N-첸GM
FX2N-첸PG QD75첸
22
MR-J3-Super 2008 UK-neu.prn
MR-J3-Super 2008 UK
Montag, 21. April 2008 13:32:45
Farbprofil: Deaktiviert
Komposit Standardbildschirm