Specifications
PURY-P YHM-A(-BS)
OUTDOOR UNIT
R2 Series
Specifications
Power source
Cooling capacity
(Nominal)
Temp.
range of
cooling
Heating capacity
(Nominal)
Temp.
range
of heating
Indoor unit
connectable
Sound pressure level
(measured in anechoic room)
Diameter of
refrigerant pipe
External finish
External dimension H ✕ W ✕ D
Net weight
Heat exchanger
Compressor
FAN
Protection
Refrigerant
Optional parts
Power input
Current input
COP (kW/kW)
Indoor
Outdoor
Power input
Current input
COP (kW/kW)
Indoor temp.
Outdoor temp.
Total capacity
Model/Quantity
High pressure
Low pressure
Type
Starting method
Motor output
Air flow rate
Type ✕ Quantity
Motor output
High pressure protection
Inverter circuit (COMP./FAN)
Compressor
Type ✕ Original charge
PURY-P350YHM-A(-BS) PURY-P400YHM-A(-BS)
kW
BTU/h
kW
A
W.B.
D.B.
kW
BTU/h
kW
A
D.B.
W.B.
dB<A>
mm(in.)
mm(in.)
mm
in.
kg (lbs)
kW
m
3
/min
L/s
cfm
kW
❇1
❇1
❇2
❇2
40.0
136,500
12.47
21.0-19.9-19.2
3.20
45.0
153,500
12.47
21.0-19.9-19.2
3.60
P15 ~ P250 / 1 ~ 35
60
ø19.05 (ø3/4) Brazed
ø28.58 (ø1-1/8) Brazed
1,710 (1,650 without legs)
✕
1,220
✕
760
67-3/8 (65 without legs)
✕
48-1/16
✕
29-15/16
265 (584)
10.3
225
3,750
7,945
Propeller fan ✕ 1
0.92
R410A ✕ 11.8kg (26 lbs)
joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J
BC controller : CMB-P104, 105, 106, 108, 1010, 1013, 1016V-G
Main BC controller : CMB-P108, 1010, 1013, 1016V-GA
Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB
45.0
153,500
13.74
23.1-22.0-21.2
3.27
50.0
170,600
13.71
23.1-21.9-21.1
3.64
P15 ~ P250 / 1 ~ 40
61
ø22.2 (ø7/8) Brazed
ø28.58 (ø1-1/8) Brazed
1,710 (1,650 without legs)
✕
1,220
✕
760
67-3/8 (65 without legs)
✕
48-1/16
✕
29-15/16
265 (584)
10.5
225
3,750
7,945
Propeller fan ✕ 1
0.92
R410A ✕ 11.8kg (26 lbs)
joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J
Main BC controller : CMB-P108, 1010, 1013, 1016V-GA
Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB
3-phase 4-wire 380-400-415V 50/60Hz
15 ~ 24˚C (59 ~ 75˚F)
- 5 ~ 43˚C (23 ~ 109˚F)
15 ~ 27˚C (59 ~ 81˚F)
-20 ~ 15.5˚C (-4 ~ 60˚F)
50 ~ 150% of outdoor unit capacity
Pre-coated galvanized steel sheet (+powder coating for -BS type) <MUNSELL 5Y 8/1>
Salt-resistant cross fin & copper tube
Inverter scroll hermetic compressor
Inverter
High pressure sensor, High pressure switch 4.15 MPa (601 psi)
Over-heat protection, Over-current protection
Over-heat protection
Note:
❇1 Nominal cooling conditions
Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB
Pipe length 7.5 m (24-9/16 ft), Level difference 0 m (0 ft)
❇2 Nominal heating conditions
Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB
Pipe length 7.5 m (24-9/16 ft), Level difference 0 m (0 ft)
❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation.
❇3
❇3
Page118
Outdoor Unit
PURY-P YHM-A(-BS)
OUTDOOR UNIT
R2 Series
Specifications
Power source
Cooling capacity
(Nominal)
Temp.
range of
cooling
Heating capacity
(Nominal)
Temp.
range
of heating
Indoor unit
connectable
Sound pressure level
(measured in anechoic room)
Diameter of
refrigerant pipe
External finish
External dimension H ✕ W ✕ D
Net weight
Heat exchanger
Compressor
FAN
Protection
Refrigerant
Optional parts
Power input
Current input
COP (kW/kW)
Indoor
Outdoor
Power input
Current input
COP (kW/kW)
Indoor temp.
Outdoor temp.
Total capacity
Model/Quantity
High pressure
Low pressure
Type
Starting method
Motor output
Air flow rate
Type ✕ Quantity
Motor output
High pressure protection
Inverter circuit (COMP./FAN)
Compressor
Type ✕ Original charge
PURY-P200YHM-A(-BS) PURY-P250YHM-A(-BS) PURY-P300YHM-A(-BS)
kW
BTU/h
kW
A
W.B.
D.B.
kW
BTU/h
kW
A
D.B.
W.B.
dB<A>
mm(in.)
mm(in.)
mm
in.
kg (lbs)
kW
m
3
/min
L/s
cfm
kW
❇1
❇1
❇2
❇2
22.4
76,400
5.77
9.7-9.2-8.9
3.88
25.0
85,300
6.14
10.3-9.8-9.4
4.07
P15 ~ P250 / 1 ~ 20
56
ø15.88 (ø5/8) Brazed
ø19.05 (ø3/4) Brazed
1,710 (1,650 without legs)
✕
920
✕
760
67-3/8 (65 without legs)
✕
36-1/4
✕
29-15/16
220 (485)
5.4
185
3,083
6,532
Propeller fan ✕ 1
0.92
R410A ✕ 8.0kg (18 lbs)
28.0
95,500
7.73
13.0-12.3-11.9
3.62
31.5
107,500
7.83
13.2-12.5-12.1
4.02
P15 ~ P250 / 1 ~ 25
57
ø19.05 (ø3/4) Brazed
ø22.2 (ø7/8) Brazed
1,710 (1,650 without legs)
✕
920
✕
760
67-3/8 (65 without legs)
✕
36-1/4
✕
29-15/16
235 (518)
6.7
185
3,083
6,532
Propeller fan ✕ 1
0.92
R410A ✕ 10.5kg (24 lbs)
33.5
114,300
9.25
15.6-14.8-14.2
3.62
37.5
128,000
9.58
16.1-15.3-14.8
3.91
P15 ~ P250 / 1 ~ 30
59
ø19.05 (ø3/4) Brazed
ø22.2 (ø7/8) Brazed
1,710 (1,650 without legs) ✕ 920 ✕ 760
67-3/8 (65 without legs) ✕ 36-1/4 ✕ 29-15/16
240 (529)
8.2
185
3,083
6,532
Propeller fan ✕ 1
0.92
R410A ✕ 10.5kg (24 lbs)
joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-Y202-G2, CMY-R160-J
BC controller : CMB-P104, 105, 106, 108, 1010, 1013, 1016V-G
Main BC controller : CMB-P108, 1010, 1013, 1016V-GA
Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB
3-phase 4-wire 380-400-415V 50/60Hz
15 ~ 24˚C (59 ~ 75˚F)
- 5 ~ 43˚C (23 ~ 109˚F)
15 ~ 27˚C (59 ~ 81˚F)
-20 ~ 15.5˚C (-4 ~ 60˚F)
50 ~ 150% of outdoor unit capacity
Pre-coated galvanized steel sheet (+powder coating for -BS type) <MUNSELL 5Y 8/1>
Salt-resistant cross fin & copper tube
Inverter scroll hermetic compressor
Inverter
High pressure sensor, High pressure switch 4.15 MPa (601 psi)
Over-heat protection, Over-current protection
Over-heat protection
Note:
❇1 Nominal cooling conditions
Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB
Pipe length 7.5 m (24-9/16 ft), Level difference 0 m (0 ft)
❇2 Nominal heating conditions
Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB
Pipe length 7.5 m (24-9/16 ft), Level difference 0 m (0 ft)
❇3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation.
❇3
❇3
joint : CMY-Y102S-G2, CMY-Y102L-G2, CMY-R160-J
BC controller : CMB-P104, 105, 106, 108, 1010, 1013, 1016V-G
Main BC controller : CMB-P108, 1010, 1013, 1016V-GA
Sub BC controller : CMB-P104, 108V-GB, CMB-P1016V-HB
Page117
Outdoor unit