Specifications

PUHY-P YHM-A(-BS)
OUTDOOR UNIT
Y Series
Specifications
Power source
Cooling capacity
(Nominal)
Temp.
range of
cooling
Heating capacity
(Nominal)
Temp.
range
of heating
Indoor unit
connectable
Sound pressure level
(measured in anechoic room)
Diameter of
refrigerant pipe
External finish
External dimension H W D
Net weight
Heat exchanger
Compressor
FAN
Protection
Refrigerant
Optional parts
45.0
153,500
13.23
22.3-21.2-20.4
3.40
50.0
170,600
13.47
22.7-21.6-20.8
3.71
P15~P250 / 1~34
61
ø12.7 (ø1/2)
Brazed
ø28.58 (ø1-1/8) Brazed
1,710(without legs 1,650) 1,220 760
67-3/8(without legs 65) 5 48-1/16 5 29-15/16
245 (541)
10.5
225
3,750
7,945
Propeller fan 1
0.46 1
R410A 11.5kg (26 lbs)
joint : CMY-Y102S / L-G2, CMY-Y202-G2
Header : CMY-Y104 / 108 / 1010-G
50.0
170,600
16.28
27.4-26.1-25.1
3.07
56.0
191,100
15.38
25.9-24.6-23.7
3.64
P15~P250 / 1~39
62
ø15.88 (ø5/8)
Brazed
ø28.58 (ø1-1/8) Brazed
1,710(without legs 1,650) 1,220 760
67-3/8(without legs 65) 5 48-1/16 5 29-15/16
245 (541)
12.0
225
3,750
7,945
Propeller fan 1
0.46 1
R410A 11.5kg (26 lbs)
Power input
Current input
COP (kW/kW)
Indoor
Outdoor
Power input
Current input
COP (kW/kW)
Indoor temp.
Outdoor temp.
Total capacity
Model/Quantity
Liquid
Gas
Type
Starting method
Motor output
Air flow rate
Type Quantity
Motor output
High pressure protection
Inverter circuit (COMP./FAN)
Compressor
Type Original charge
kW
BTU/h
kW
A
W.B.
D.B.
kW
BTU/h
kW
A
D.B.
W.B.
dB<A>
mm(in.)
mm(in.)
mm
in.
kg(lbs)
kW
m
3
/min
L/s
cfm
kW
1
1
2
2
PUHY-P400YHM-A(-BS) PUHY-P450YHM-A(-BS)
Note:
1 Nominal cooling conditions
Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB
Pipe length 7.5 m (24-9/16 ft), Level difference 0 m (0 ft)
2 Nominal heating conditions
Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB
Pipe length 7.5 m (24-9/16 ft), Level difference 0 m (0 ft)
3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation.
15~24˚C (59~75˚F)
- 5~43˚C (23~109˚F)
15~27˚C (59~81˚F)
-20~15.5˚C (-4~60˚F)
50~130% of outdoor unit capacity
Pre-coated galvanized steel sheets (+ powder coating for-BS type) <MUNSELL 5Y 8/1 or similar>
Salt-resistant cross fin & copper tube
Inverter scroll hermetic compressor
Inverter
High pressure sensor, High pressure switch 4.15 MPa (601 psi)
Over-heat protection, Over-current protection
Over-heat protection
3-phase 4-wire 380-400-415V 50/60Hz
PUHY-P350YHM-A(-BS)
40.0
136,500
11.20
18.9-17.9-17.3
3.57
45.0
153,500
12.09
20.4-19.3-18.6
3.72
P15~P250 / 1~30
60
ø12.7 (ø1/2) Brazed
ø28.58 (ø1-1/8) Brazed
1,710(without legs 1,650) 1,220 760
67-3/8(without legs 65) 5 48-1/16 5 29-15/16
245 (541)
10.3
225
3,750
7,945
Propeller fan 1
0.46 1
R410A 11.5kg (26 lbs)
3
3
Page100
Outdoor Unit
PUHY-P YHM-A(-BS)
OUTDOOR UNIT
Y Series
Specifications
Power source
Cooling capacity
(Nominal)
Temp.
range of
cooling
Heating capacity
(Nominal)
Temp.
range
of heating
Indoor unit
connectable
Sound pressure level
(measured in anechoic room)
Diameter of
refrigerant pipe
External finish
External dimension H W D
Net weight
Heat exchanger
Compressor
FAN
Protection
Refrigerant
Optional parts
Power input
Current input
COP (kW/kW)
Indoor
Outdoor
Power input
Current input
COP (kW/kW)
Indoor temp.
Outdoor temp.
Total capacity
Model/Quantity
Liquid
Gas
Type
Starting method
Motor output
Air flow rate
Type Quantity
Motor output
High pressure protection
Inverter circuit (COMP. / FAN)
Compressor
Type Original charge
kW
BTU/h
kW
A
W.B.
D.B.
kW
BTU/h
kW
A
D.B.
W.B.
dB<A>
mm(in.)
mm(in.)
mm
in.
kg(lbs)
kW
m
3
/min
L/s
cfm
kW
1
1
2
2
PUHY-P200YHM-A(-BS) PUHY-P250YHM-A(-BS) PUHY-P300YHM-A(-BS)
22.4
76,400
5.72
9.6-9.1-8.8
3.91
25.0
85,300
6.03
10.1-9.6-9.3
4.14
P15~P250 / 1~17
56
ø9.52 (ø3/8) Brazed
ø19.05 (ø3/4) Brazed
1,710(without legs 1,650) 920 760
67-3/8(without legs 65) 36-1/4 29-15/16
185 (408)
5.4
185
3,083
6,532
Propeller fan 1
0.46 1
R410A 6.5kg (15 lbs)
joint : CMY-Y102S-G2
Header : CMY-Y104 / 108 / 1010-G
28.0
95,500
7.73
13.0-12.3-11.9
3.62
31.5
107,500
7.83
13.2-12.5-12.1
4.02
P15~P250 / 1~21
57
ø9.52 (ø3/8) Brazed
(ø12.7 (ø1/2) Brazed , total length >=90m)
ø22.2 (ø7/8) Brazed
1,710(without legs 1,650) 920 760
67-3/8(without legs 65) 36-1/4 29-15/16
210 (463)
6.7
185
3,083
6,532
Propeller fan 1
0.46 1
R410A 9.0kg (20 lbs)
33.5
114,300
9.07
15.3-14.5-14.0
3.69
37.5
128,000
9.39
15.8-15.0-14.5
3.99
P15~P250 / 1~26
59
ø9.52 (ø3/8) Brazed
(ø12.7 (ø1/2) Brazed , total length>=40m)
ø22.2 (ø7/8) Brazed
1,710(without legs 1,650) 920 760
67-3/8(without legs 65) 36-1/4
29-15/16
215 (474)
8.2
185
3,083
6,532
Propeller fan 1
0.46 1
R410A 9.0kg (20 lbs)
3-phase 4-wire 380-400-415V 50/60Hz
15~24˚C(59~75˚F)
- 5~43˚C(23~109˚F)
15~27˚C(59~81˚F)
-20~15.5˚C(-4~60˚F)
50~130% of outdoor unit capacity
Salt-resistant cross fin & copper tube
Inverter scroll hermetic compressor
Inverter
Pre-coated galvanized steel sheets (+ powder coating for-BS type) <MUNSELL 5Y 8/1 or similar>
High pressure sensor, High pressure switch 4.15 MPa (601 psi)
Over-heat protection, Over-current protection
Over-heat protection
Note:
1 Nominal cooling conditions
Indoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DB
Pipe length 7.5 m (24-9/16 ft), Level difference 0 m (0 ft)
2 Nominal heating conditions
Indoor 20˚C (68˚F) DB,Outdoor 7˚C (45˚F) DB/6˚C (43˚F) WB
Pipe length 7.5 m (24-9/16 ft), Level difference 0 m (0 ft)
3 -5˚C (23˚F) DB/-6˚C (21˚F) WB~21˚C (70˚F) DB/15.5˚C (60˚F) WB with cooling/heating mixed operation.
3
3
joint : CMY-Y102S / L-G2
Header : CMY-Y104 / 108 / 1010-G
Page99