Specifications

Specifications
Note:
1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling : Indoor 27˚C(81˚F)DB/19˚C(66˚F)WB,Outdoor 35˚C(95˚F)DB
Heating : Indoor 20˚C(68˚F)DB,Outdoor 7˚C(45˚F)DB/6˚C(43˚F)WB
2 Airflow rate/Sound pressure level are in (low-middle-high) or (low-middle2-middle1-high).
3 It is measured in anechoic room.
PLFY-P20VLMD-E PLFY-P25VLMD-E
PLFY-P32VLMD-E PLFY-P40VLMD-E
1-phase 220-240V 50Hz / 1-phase 220-230V 60Hz
Galvanized steel plate
Pure white (6.4Y 8.9/0.4)
290 776 634 (11-7/16 30-9/16 25)
20 1080 710 (13/16 42-9/16 28)
6.5 (15)
Cross fin
Turbo fan
1
23 (51) 24 (53)
0
1-phase induction motor
0.015 (at 240V)
PP honeycomb fabric (long life type)
ø12.7 (ø
1/2)
ø6.35 (ø1/4)
O.D.32 (1-1/4)
6.5-8.0-9.5
108-133-158
230-283-335
7.0-8.5-10.5
117-142-175
247-300-371
2.2
7,500
2.5
8,500
0.072 / 0.075
0.065 / 0.069
0.36 / 0.37
0.30 / 0.32
2.8
9,600
3.2
10,900
0.072 / 0.075
0.065 / 0.069
0.36 / 0.37
0.30 / 0.32
3.6
12,300
4.0
13,600
0.072 / 0.075
0.065 / 0.069
0.36 / 0.37
0.30 / 0.32
4.5
15,400
5.0
17,100
0.081 / 0.085
0.074 / 0.079
0.40 / 0.42
0.34 / 0.37
27-30-33
28-31-34
29-33-36
30-34-37
kW
BTU/h
kW
BTU/h
kW
kW
A
A
mm (in.)
mm (in.)
kg(lbs.)
kg(lbs.)
m
3
/min
L/s
cfm
Pa
kW
mm(in.)
mm(in.)
mm(in.)
dB(A)
dB(A)
1
1
1
1
Cooling
Heating
Cooling
Heating
Unit
Panel
Unit
Panel
Unit
Panel
Type
Quantity
Airflow rate
(Lo-Mid-Hi)
External static pressure
Type
Output
Gas(Flare)
Liquid(Flare)
2 3
2 3
220V,240V
230V
kW
BTU/h
kW
BTU/h
kW
kW
A
A
mm (in.)
mm (in.)
kg(lbs.)
kg(lbs.)
m
3
/min
L/s
cfm
Pa
kW
mm(in.)
mm(in.)
mm(in.)
dB(A)
dB(A)
1
1
1
1
Cooling
Heating
Cooling
Heating
Unit
Panel
Unit
Panel
Unit
Panel
Type
Quantity
Airflow rate
(P50~P100:Lo-Mid-Hi)
(P125:Lo-Mid2-Mid1-Hi)
External static pressure
Type
Output
Gas
(Flare)
Liquid
(Flare)
2
220V,240V
230V
PLFY-P63VLMD-E PLFY-P80VLMD-E PLFY-P100VLMD-E PLFY-P125VLMD-E
1-phase 220-240V 50Hz / 1-phase 220-230V 60Hz
Galvanized steel plate
Pure white (6.4Y 8.9 / 0.4)
Turbo fan 1 Turbo fan 2
12.5 (28)7.5 (17)
ø15.88 (ø5/8)
ø9.52 (ø3/8)
11.0-13.0-15.5
167-217-258
353-459-547
17.5-21.0-25.0
292-350-417
618-742-883
0.030 (at 240V)
15.5-18.5-22.0
258-308-367
547-653-777
0
1-phase induction motor
0.020 (at 240V)
0.020 (at 240V)
7.1
24,200
8.0
27,300
0.101 / 0.105
0.094 / 0.099
0.49 / 0.51
0.43 / 0.46
28 (62)
9.0
30,700
10.0
34,100
0.147 / 0.156
0.140 / 0.150
0.72 / 0.74
0.66 / 0.69
44 (98)
Cross fin
11.2
38,200
12.5
42,700
0.157 / 0.186
0.150 / 0.180
0.75 / 0.88
0.69 / 0.83
47 (104)
14.0
47,800
16.0
54,600
0.28 / 0.28
0.27 / 0.27
1.35 / 1.35
1.33 / 1.33
56 (124)
13.0 (29)
Sirocco fan
4
24.0-27.0-30.0-33.0
400-450-500-550
848-953-1,059-1,165
0.078
2 (at 240V)
Synthetic fiber unwoven
cloth filter (long life)
O.D.32 (1-1/4)
33-36-39
34-37-40
PLFY-P50VLMD-E
PP honeycomb fabric (long life type)
5.6
19,100
6.3
21,500
0.082 / 0.086
0.075 / 0.080
0.41 / 0.43
0.35 / 0.38
27 (60)
31-34-37
32-35-38
32-37-39
33-38-40
40-42-44-46
(Lo-Mid2-Mid1-Hi)
ø12.7 (ø1/2)
ø6.35 (ø1/4)
36-39-42
37-41-43
290
946 634 (11-7/16 37-1/4 25)
20 1250 710 (13/16 49-1/4 28)
290 1446 634 (11-7/16 56-15/16 25)
20 1750 710 (13/16 68-15/16 28)
290 1708 606 (11-7/16 67-1/4 23-7/8)
20 2010 710 (13/16 79-3/16 28)
9.0-11.0-12.5
150-183-208
318-388-441
Power source
Cooling capacity
Heating capacity
Power
consumption
Current
External finish
(Munsell No.)
Dimension
H W D
Net weight
Heat exchanger
Fan
Motor
Air filter
Refrigerant
pipe diameter
Field drain pipe diameter
Sound pressure level
(Lo-Mid-Hi)
Power source
Cooling capacity
Heating capacity
Power
consumption
Current
External finish
(Munsell No.)
Dimension
H W D
Net weight
Heat exchanger
Fan
Motor
Air filter
Refrigerant
pipe diameter
Field drain pipe diameter
Sound pressure level
(Lo-Mid-Hi)
2
Page44
Specifications
INDOOR UNIT
Ceiling cassette type
2-way airflow
PLFY-P VLMD-E
Fresh air can be taken in to the main unit directly (optional ac-
cessories needed.)
The drain can be positioned anywhere up to 583mm(22-15/16in.)
from the ceiling's surface, providing greater freedom with long
cross-piping and allowing more versatility with piping layouts.
Equipped with drain pump
mechanism as standard
Terminal block on outside of main unit
makes wiring easier
Compact unit and low noise level attained!
Fresh air directly taken in
The slimline body is highly suitable for installation in narrow
ceiling spaces and for replacing obsolete air-conditioning
equipment in older buildings. The main unit is only 290mm(11-
7/16in.) height.
Slim body - only 290mm(11-7/16in.) height
Ceiling surface
Drain height
max. 583(22-15/16)
Main unit height - 290(11-7/16)
583
290mm
(11-7/16in.)
The antibacterial long life filter does not require maintenance
for approximately a year.
Long life filter equipped as standard
Lighter panel and placing the electric board near the panel
make installation and maintenance easier. Also, the heat ex-
changer is washable by displacing the center panel, filter, and
fan.
Easy installation
Slim body of 290mm(11-7/16in.) height
mm (in.)
Capacity P25
33
30
27
P32 P40
36
33
29
P50
37
34
31
P63
39
37
32
P80
39
36
33
P100
42
39
36
P125
46
40
42/44
Sound
pressure
Level
dB(A)
Sound pressure level table (Standard static pressure) at 0Pa
<220V,240V>
High
Mid
Low
P20
Fan
Speed
Capacity P25
34
31
28
P32 P40
37
34
30
P50
38
35
32
P63
40
38
33
P80
40
37
34
P100
43
41
37
P125
46
40
42/44
Sound
pressure
Level
dB(A)
<230V>
High
Mid
Low
P20
Fan
Speed
Page43
Indoor unit