User`s manual

(2/n)
LEN130391
CONTENTS
1. General Description............................................................................................................................... 3
2. Specification ..........................................................................................................................................
4
3. Configuration Conditions of CC-Link System ........................................................................................ 5
3.1 Remote net ver.2 mode, remote net addional mode ...................................................................... 5
4. Programming.........................................................................................................................................
7
4.1 Programming Procedure ................................................................................................................ 7
5. Parameter Settings................................................................................................................................8
5.1 Procedure from Parameter Settings to Data Link Startup .............................................................. 8
5.1.1 CPU Parameter Area and Master Module Parameter Memory............................................ 8
5.1.2 Procedure for Parameter Settings to Data Link Startup with GX Developer ........................ 8
5.2 Example of Parameter Settings with GX Developer (Remote net ver.2 mode) .............................. 9
5.2.1 Master Station Network Parameter Settings........................................................................ 9
6. Communication Between the Master Station and ME96 ..................................................................... 13
6.1 Communication Guideline ............................................................................................................ 13
6.2 Initial Communication................................................................................................................... 14
6.3 Error Communication ................................................................................................................... 14
6.4 Normal Communication................................................................................................................ 15
6.4.1 Monitoring by Pattern ........................................................................................................ 15
6.4.2 Monitoring by Command(1H) ............................................................................................ 16
6.4.3 Setting by Command(2H) .................................................................................................. 17
7. Remote I/O and Remote Register ....................................................................................................... 18
7.1 Remote Input RX, Remote Output RY ......................................................................................... 18
7.1.1 Remote input RX ............................................................................................................... 18
7.1.2 Remote Output RY ............................................................................................................ 20
7.2 Remote Register (RWr, RWw)...................................................................................................... 22
7.2.1 When Monitoring by Pattern .............................................................................................. 25
7.2.2 When Monitoring by Command(1H) .................................................................................. 28
7.2.3 When Setting by Command(2H)........................................................................................ 40
7.2.4 Data format of Monitoring by Command(1H) and Setting by Command(2H)..................... 43
7.2.5 Multiplying factor ............................................................................................................... 53
7.2.6 About Error Occurrence..................................................................................................... 54
8. Abbreviations and Special Terms ........................................................................................................ 55
9. Program Example................................................................................................................................
56
9.1 Program Content.......................................................................................................................... 56
9.2 System Configuration................................................................................................................... 56
9.3 Parameter Settings ...................................................................................................................... 57
9.3.1 Network Parameter Settings and Auto
Refresh Parameter Settings ................................. 57
9.3.2 Operational Settings.......................................................................................................... 58
9.3.3 Station Information Settings............................................................................................... 58
9.4 Device Allocation.......................................................................................................................... 59
9.5 Program Example ........................................................................................................................ 61
10. Test Mode............................................................................................................................................
66
10.1 ME96SSH-MB/ME96SSR-MB...................................................................................................... 66