User`s manual

(1) Relationships between programmable controller CPU, master module and ME96(RX)
1) The input status of ME96 is stored automatically (for each link scan) in the master station's
"remote input RX" buffer memory.
1) The input status of ME96 is stored automatically (for each link scan) in the master station's
"remote input RX" buffer memory.
2) The input status stored in the "remote input RX" buffer memory is stored in the CPU device set
with the automatic refresh parameters.
2) The input status stored in the "remote input RX" buffer memory is stored in the CPU device set
with the automatic refresh parameters.
1) Relationships between programmable controller CPU, master module and ME96(RX)
(19/n)
LEN130391
Station Station
number number
Device No. Device No.
StationStation
numbernumber
Device No. Device No.
StationStation
numbernumber
Device No. Device No.
1 X1000 to X107F 15 X1700 to X177F 29 X1E00 to X1E7F
2 X1080 to X10FF 16 X1780 to X17FF 30 X1E80 to X1EFF
3 X1100 to X117F 17 X1800 to X187F 31 X1F00 to X1F7F
4 X1180 to X11FF 18 X1880 to X18FF 32 X1F80 to X1FFF
5 X1200 to X127F 19 X1900 to X197F 33 X2000 to X207F
6 X1280 to X12FF 20 X1980 to X19FF 34 X2080 to X20FF
7 X1300 to X137F 21 X1A00 to X1A7F 35 X2100 to X217F
8 X1380 to X13FF 22 X1A80 to X1AFF 36 X2180 to X21FF
9 X1400 to X147F 23 X1B00 to X1B7F 37 X2200 to X227F
10 X1480 to X14FF 24 X1B80 to X1BFF 38 X2280 to X22FF
11 X1500 to X157F 25 X1C00 to X1C7F 39 X2300 to X237F
12 X1580 to X15FF 26 X1C80 to X1CFF 40 X2380 to X23FF
13 X1600 to X167F 27 X1D00 to X1D7F 41 X2400 to X247F
14 X1680 to X16FF 28 X1D80 to X1DFF 42 X2480 to X24FF
Device No. is determined to “X1000 to X24FF” if refresh device of remote input (RX) is set to “X1000”.
Device X
X1000 to X100F
X1010 to X101F
X1020 to X102F
ME96 X1030 to X103F
(Station number1) X1040 to X104F
X1050 to X105F
X1060 to X106F
X1070 to X107F
ME96 X1000 to X100F
(Station number2) to
X10F0 to X10FF
to
ME96 X2480 to X248F
(Station number42) to
X24F0 to X24FF
Remote input(RX)
RX00 to RX0F
RX10 to RX1F
RX20 to RX2F
RX30 to RX3F
RX40 to RX4F
RX50 to RX5F
RX60 to RX6F
RX70 to RX7F
RX80 to RX8F
RXF0 to RXFF
to
RX1480 to RX148F
to
RX14F0 to RX14FF
Programmable controller CPU Master module ME96(Station number 1)
Remote input(RX)
RX00 to RX0F
RX10 to RX1F
RX20 to RX2F
RX30 to RX3F
RX40 to RX4F
1)
RX50 to RX5F
RX60 to RX6F
RX70 to RX7F
ME96(Station number 2)
Remote input(RX)
RX00 to RX0F
to
RX70 to RX7F
ME96(Station number 42)
to
Remote input(RX)
RX00 to RX0F
to
RX70 to RX7F
2)
2)
1)
2)
1)