ABOUT THE GENERIC TERMS AND ABBREVIATIONS
Unless otherwise specified, the following generic terms and abbreviations are used
in this manual to describe Type AJ65SBT-64AD analog-digital converter module.
Generic Term/Abbreviation Description
GX Developer
Product name of the software package for the MELSEC programmable controllers
GX Works2
ACPU
Generic term for A0J2CPU, A0J2HCPU, A2CPU, A2CPU-S1, A3CPU, A1SCPU,
A1SCPU-S1, A1SCPUC-24-R2, A1SHCPU, A1SJCPU, A1SJCPU-S3, A1SJHCPU,
A1NCPU, A2NCPU, A2NCPU-S1, A3NCPU, A3MCPU, A3HCPU, A2SCPU,
A2SCPU-S1, A2SHCPU, A2SHCPU-S1, A2ACPU, A2ACPU-S1, A3ACPU, A2UCPU,
A2UCPU-S1, A2ASCPU, A2ASCPU-S1, A2ASCPU-S30, A2USHCPU-S1, A3UCPU,
A4UCPU
QnACPU
Generic term for Q2ACPU, Q2ACPU-S1, Q2ASCPU, Q2ASCPU-S1, Q2ASHCPU,
Q2ASHCPU-S1, Q3ACPU, Q4ACPU, Q4ARCPU
QCPU (A mode)
Generic term for Q02CPU-A, Q02HCPU-A, Q06HCPU-A
QCPU (Q mode)
Generic term for Q00JCPU, Q00UJCPU, Q00CPU, Q00UCPU, Q01CPU, Q01UCPU,
Q02CPU, Q02HCPU, Q02PHCPU, Q02UCPU, Q03UDCPU, Q03UDECPU,
Q03UDVCPU, Q04UDHCPU, Q04UDEHCPU, Q04UDVCPU, Q06HCPU,
Q06PHCPU, Q06UDHCPU, Q06UDEHCPU, Q06UDVCPU, Q10UDHCPU,
Q10UDEHCPU, Q12HCPU, Q12PHCPU, Q12PRHCPU, Q13UDHCPU,
Q13UDEHCPU, Q13UDVCPU, Q20UDHCPU, Q20UDEHCPU, Q25HCPU,
Q25PHCPU, Q25PRHCPU, Q26UDHCPU, Q26UDEHCPU, Q26UDVCPU,
Q50UDEHCPU, and Q100UDEHCPU
LCPU
Generic term for L02SCPU, L02SCPU-P, L02CPU, L02CPU-P, L06CPU, L06CPU-P,
L26CPU, L26CPU-P, L26CPU-BT, and L26CPU-PBT
RCPU
Generic term for R04CPU, R08CPU, R16CPU, R32CPU, and R120CPU
Master station
Station that controls the data link system.
One master station is required for each system.
Local station
Station having a PLC CPU and the ability to communicate with the master and other
local stations.
Remote I/O station
Remote station that handles bit unit data only. (Performs input and output with
external devices.) (AJ65BTB1-16D, AJ65SBTB1-16D)
Remote device station
Remote station that handles bit unit and word unit data only. (Performs input and
output with external devices, and analog data exchange.)
Remote station
Generic term for remote I/O station and remote device station
(Controlled by the master station)
Intelligent device station
Station that can perform transient transmission, such as the AJ65BT-R2N (including
local stations).
Master module
Generic term for modules that can be used as the master station
SB
Link special relay (for CC-Link)
Bit unit information that indicates the module operating status and data link status of
the master station/local station.
SW
Link special register (for CC-Link)
16 bit unit information that indicates the module operating status and data link status
of the master station/local station.
RX
Remote input (for CC-Link)
Information entered in bit units from the remote station to the master station.
RY
Remote output (for CC-Link)
Information output in bit units from the master station to the remote station.
RWw
Remote register (Write area for CC-Link)
Information output in 16-bit units from the master station to the remote device station.
RWr
Remote register (Read area for CC-Link)
Information entered in 16-bit units from the remote device station to the master station.