User`s manual
7
3.2 Cable for Connection between Terminal Block Conversion Module and
Numeric Keypad Panel
Fabricate the cable for connection between terminal block conversion module
and Numeric Keypad Panel in accordance with the following wiring diagram,
parts list and assembly diagram (max. cable length: 10m (32.79feet)).
(1) Wiring diagram
(a) For use of the terminal block conversion module (A6TBY36-E)
12/24VDC
0 3 4 5 6 71 2-C -C -C -C
10 11
8
12 13 14 15 16 17 18 19 1A-C -C -C -C -C -C 1B 1C 1D
XSCN
0
XSCN1
XSCN2
XSCN3
XSCN4
XSCN5
XSCN6
XSCN7
Terminal block conversion module
9
A-C -C B C D E-C -C F -C
1F1E-C -C -C 24V 0V
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Loads:Lamps,relays,etc.
(A6TBY36-E)
XD0 XD1 XD2 XD3 XD4
XD5 XD6 XD7
F8
F7
F6
F5
F4
F3
F2
F1
F9
F10
SP
SCR DWN
SCR UP
6
5
4
9
8
7
BS
0
-
3
2
1
.
Numeric Keypad Panel