Specifications

[Issue No.] GOT-A-0018-G [Page] 22/27
[Title] Precautions when Replacing GOTA800, A77GOT, A64GOT Series with GOT1000 Series
[Date of Issue] Ver.G: September 2011 (First Edition: September 2005)
[Relevant Models] GOT800, A77GOT, and A64GOT Series
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
TECHNICAL BULLETIN
7.2 Compatibility of monitor screen data
7.2.1 Data compatibility list
To convert GOT800, A77GOT, or A64GOT series drawing data into GOT1000 series drawing data, some
functions have restrictions or cannot be converted. For the A77GOT or A64GOT series data, convert the data
into the GOT800 series monitor screen data by using the GOT800 series drawing software
(SW3NIW-A8GOTP9). Then, convert the data into the GOT1000 series drawing data by using GT Converter2
Version.
For whether the data can be converted into the GOT1000 series drawing data, refer to the following table.
Table7-1 Availability of functions on GOT1000 series after conversion
: Available, : Available (The partial setting change may be required.),
<>: N/A (Conversion unavailable, available with new setting), ×: N/A,
: Unsupported function
Whether the function is
available for GOT1000
series after conversion
Function
GOT
800
A77
GOT
A64
GOT
Remarks (Precautions)
Numerical display *1
ASCII display *1
Quarter characters are converted into quad characters. Therefore, set
the character display size to quarter size.
*1: When this object is overlapped with the other objects (example:
trend graph), set the layer for the object to [Front].
String display - *1
The function is converted into the ASCII display.
*1: When this object is overlapped with the other objects (example:
trend graph), set the layer for the object to [Front].
Comment display - - -
Clock display *1
*1: When this object is overlapped with the other objects (example:
trend graph), set the layer for the object to [Front].
Alarm list display *1 -
*1: When this object is overlapped with the other objects (example:
trend graph), set the layer for the object to [Front].
Alarm history display - - -
Level display -
Lamp display - - -
Panel meter - - -
Parts display
Part display setting alone to which the part number is not changed
cannot be used. (substantially impossible setting)
Movement (Parts movement) -
Locus (Parts movement) -
Error warning display - <> <> Configure the new setting for the alarm list display function.
Numerical value - Block
data
display
ASCII -
The function is converted into multiple numerical displays and ASCII
displays.Quarter characters are converted into quad characters.
Therefore, set the character display size to quarter size.
Data
display
function
Data list display - - -
Scroll 
Up to eight lines (data) are converted per graph.
For a graph with 9 to 16 lines (data), configure the new graph setting.
Batch  <> <> Configure the new setting for the trigger of the line graph function.
Trend
graph
Overwrite - × - The GOT1000 series does not support this function. *
Line graph -
Normality  - Bar
graph
Accumulation - × - The GOT1000 series does not support this function.
Band graph - - <> Configure the new setting for the statistics graph.
Pie graph
-
<> - Configure the new setting for the statistics graph.
Scatter graph - <> <>
The GOT800 series does not support this function. Therefore, when
replacing the A77GOT or A64GOT series data, configure the new
setting with GT Designer2.
Graph
display
function
Spline graph - × - The GOT1000 series does not support this function.
Numerical input *1 Data
input
function
ASCII input
*1
*1: When this object is overlapped with the other objects (example:
trend graph), set the layer for the object to [Front].