Specifications
[Issue No.] GOT-A-0018-G [Page] 17/27
[Title] Precautions when Replacing GOTA800, A77GOT, A64GOT Series with GOT1000 Series
[Date of Issue] Ver.G: September 2011 (First Edition: September 2005)
[Relevant Models] GOT800, A77GOT, and A64GOT Series
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
TECHNICAL BULLETIN
7.1.1 How to convert monitor screen data from GOT800 series to GOT1000 series
By converting the monitor screen data for the GOT800 series into the GOT1000 series data with the data
conversion software (GT Converter2 Version2 or GT Converter2 Version3), the monitor screen data for the
GOT800 series can be used for the GOT1000 series.
The data conversion software is included with the following drawing software for the GOT1000 series.
1)GT Converter2 Version2
- GT Works2 Version2(SW2D5C-GTWK2)
- GT Designer2 Version2(SW2D5C-GTD2)
2)GT Converter2 Version3
- GT Works3 Version1(SW1DNC-GTWK3)
(1) When you have the monitor screen data for the GOT800 series
Convert the GOT800 series data into the GOT1000 series data by using GT Converter2 Version□.
To edit the file after the conversion, open and edit the file with GT Designer2 Version□ or GT Works3
Version1.
< Operation of GT Converter2 Version□ >
1) Start GT Converter2 Version□.
2) Select the monitor screen data to be converted, and start conversion.
3) After the conversion is completed, name and save the file.
* The file format after conversion is “*.G1”instead of “*.GTE”.
* For the operation of GT Converter2 Version□, refer to the following manual.
1)GT Converter2 Version2
- GT Converter2 Version2 Operating Manual (SH-080533ENG)
2)GT Converter2 Version3
- GT Converter2 Version3 Operating Manual for GT Works3 (SH-080862ENG)
< Editing with GT Designer2 >
(a) GT Designer2 Version□
1) Start GT Designer2 Version□.
2) Select [Project] – [Open] from the menu.
3) Select [GOT1000 Binary Files(*.G1)] for [Files of type] in the [Open] dialog box.
4) Select the file to be edited, and then click the [Open] button.
5) Edit the file, and then save the file as a new file to create the monitor screen data (GTE file) for the
GOT1000 series.