4.2 RS-232 cable
The connectors for the GOT800 series serial communication module (RS-232) and for the GOT1000 series
serial communication port (RS-232) are the same type (9-pin D-sub (male), with inch screws). The pin locations
are also the same.
Use the Mitsubishi GOT1000 series cables (including user-created cables described in GOT1000 Series
Connection Manual) to connect to the GOT1000 series.
4.3 RS-422 cable
For the Mitsubishi GOT800 series cables in use (AC□R4 and A7GT-AC□R4), the connector for the GOT800
series cables differ from the connector for the GOT1000 series cables. Replace the cable with the GOT1000
series cable.
Use the Mitsubishi GOT1000 series cables (including user-created cables described in the GOT1000 Series
Connection Manual) to connect to the GOT1000 series.
4.4 Network cable (MELSECNET/10 and CC-Link)
The network cables for the old series are available for the GOT1000 series.
4.5 Other cables
Table 4-3 Treatment for other existing cables
Cable type Treatment
Printer cable
The GOT800 series cables are not available for the GOT1000 series since the interfaces differ between the
GOT1000 series and the GOT800 series (GOT1000 series: USB or RS-232 interface, GOT800 series:
Centronics interface).
CRT connection cable The cables for each old series (model: AC□VG) are available for the GOT1000 series.