Specifications
P.30
~
Options
P.32
~
P.42
~
P.34
~
P.50
~
A975GOT
A970GOT
A970GOT
A960GOT
GT
Works2
A985GOT-V
A985GOT
A956WGOT
P.6
~
P.4
~
P.2
~
P.8
~
P.10
~
P.12
~
P.16
~
P.18
~
P.20
~
P.22
~
P.24
~
P.26
~
P.28
~
P.38
~
P.52
~
P.54
~
P.56
~
P.59
~
P.62
~
P.58
Concept Lineup
Special report
FA integrated functions
GT
SoftGOT2
Special report
New drawing software
Special report
Gateway functions
Features and
recommended points
A95 GOT
GOT
dictionary
Connection
configuration
Bus
connection
Specifications
External
dimensions
Function list
for each model
Connectable
model list
Notes
for use
List of
products
Sales &
service network
56 57
Q00JCPU
Q00CPU
Q01CPU
Q02CPU
Q02HCPU
Q06HCPU
Q12HCPU
Q25HCPU
Q12PHCPU
Q25PHCPU
Q02CPU-A
Q02HCPU-A
Q06HCPU-A
Q2ACPU
Q2ACPU-S1
Q2AHCPU
Q2AHCPU-S1
Q3ACPU
Q4ACPU
Q4ARCPU
Q2ASCPU
Q2ASCPU-S1
Q2ASHCPU
Q2ASHCPU-S1
A2UCPU
A2UCPU-S1
A3UCPU
A4UCPU
A2ACPU
A2ACPU-S1
A3ACPU
A1NCPU
A2NCPU
A2NCPU-S1
A3NCPU
A2USCPU
A2USCPU-S1
A2USHCPU-S1
A1SCPU
A1SCPUC24-R2
A1SHCPU
A2SCPU
A2SCPU-S1
A2SHCPU
A2SHCPU-S1
A1SJCPU
A1SJCPU-S3
A1SJHCPU
A0J2HCPU
A2CCPU
A2CCPUC24
A2CJCPU
A1FXCPU
Q172CPU
Q173CPU
Q172CPUN
Q173CPUN
A273UCPU
A273UHCPU
A273UHCPU-S3
A373UCPU
A373UCPU-S3
A171SCPU
A171SCPU-S3
A171SCPU-S3N
A171SHCPU
A171SHCPUN
A172SHCPU
A172SHCPUN
A173UHCPU
A173UHCPU-S1
FX0 series
FX0S series
FX0N series
FX1 series
FX1S series
FX1N series
FX1NC series
FX2 series
FX2C series
FX2N series
FX2NC series
MELSEC-
Q series
(Q mode)
MELSEC-
Q series
(A mode)
MELSEC-
QnA series
(large type)
MELSEC-
QnA series
(small type)
MELSEC-
A series
(large type)
MELSEC-
A series
(small type)
MELSEC-
A series
Motion
controller
CPU
(Q series)
Motion
controller
CPU
(A series)
(large type)
Motion
controller
CPU
(A series)
(small type)
MELSEC-
FX series
RS-422 or RS-232 can be selected
RS-422 or RS-232 can be selected
*10: CP-217 is indispensable for CP9200SH to be connected with GOT.
*11: HMI adaptor is necessary when connected with GOT.
*12: Able to connect with CPU in DH485 network configured with SLC 500 series, MicroLogix1000/1500 series. Refer to a manual for the details.
*13: When connecting with TOOL port, AFP8550 adaptor is necessary between FP peripheral unit cable and RS-232 cable.
MELSEC-Q series
(Q mode)
MELSEC-Q series
(A mode)
MELSEC-QnA series
MELSEC-A series
Motion controller CPU
(A mode)
QJ71C24
QJ71C24-R2
QJ71CMO
A1SJ71UC24-R2
A1SJ71UC24-R4
AJ71QC24
AJ71QC24-R2
AJ71QC24-R4
AJ71QC24N
AJ71QC24N-R2
AJ71QC24N-R4
A1SJ71QC24
A1SJ71QC24-R2
A1SJ71QC24N
A1SJ71QC24N-R2
AJ71UC24
AJ71C24-S8
A1SJ71UC24-R2
A1SJ71UC24-R4
A1SJ71C24-R2
A1SJ71C24-R4
A1SCPUC24-R2
A2CCPUC24
RS-232C
RS-232C
Module connector
RS-232C
RS-422/485
RS-232C
RS-232C
RS-422
RS-232C
RS-232C
RS-422
RS-232C
RS-232C
RS-232C
RS-232C
RS-232C
RS-232C
RS-232C
RS-422/485
RS-232C
RS-422/485
RS-232C
RS-232C
RS-422/485
RS-232C
RS-232C
–
–
RS-422/485
RS-232C
RS-422/485
RS-422/485
RS-232C
RS-422/485
RS-422/485
RS-232C
RS-422/485
RS-232C
RS-422/485
RS-422
––
––
––
––
––
RS-422/485
OMRON
Upper-level link unit /
communication board
C-500-LK201-V1
C200HW-COM03
C200HW-COM06
C200H-LK202-V1
C120-LK202-V1
CS1W-SCU41
CS1W-SCB41
C500-LK201-V1
C200HW-COM02
C200HW-COM05
C200HW-COM06
C200H-LK201-V1
C120-LK201-V1
CS1W-SCU21
CS1W-SCB21
CS1W-SCU41
CS1W-SCB41
CPU ModelSeries
Computer link connection
RS-422 RS-232 RS-422 RS-232
CPU direct connection
OMRON PLC
SHARP PLC
YASKAWA Electric PLC
YASKAWA Electric
motion controller
TOSHIBA
PLC
Matsushita
Electric Works PLC
C200HS
C200H
C200H
series
CQM1
C1000H
C2000H
CV500
CV1000
CV2000
CVM1-CPU01
CVM1-CPU11
CVM1-CPU21
CS1
CJ1
JW-21CU
JW-31CUH
JW-50CUH
JW-22CU
JW-32CUH
JW-33CUH
JW-70CUH
JW-100CUH
GL60S
GL60H
GL70H
GL120
GL130
CP-9200SH
CP-9300MS
MP-920/930
MP-940
PROGIC-8
CP-9200 (H)
T2 (PU224 type)
T2E
T2N
T3
T3H
Model3000 (S3)
FP0-C16CT
FP0-C32CT
FP1-C24C
FP1-C40C
FP2
FP3
FP5
FP10 (S)
FP10SH
FP-M (C20TC)
FP-M (C32TC)
C200HX
C200HG
C200HE
Series Model name
AGOT(A985(-V)/A97 /A960/A956W/A95 GOT) SoftGOT(GT SoftGOT2)
Connection configuration Connection configuration
Bus
connection
CPU direct
connection
Computer link
connection
Ethernet
connection
*19
CPU direct
connection
MELSECNET
/H
MELSECNET
/10
Q bus
connection
*16
MELSECNET
/10
MELSECNET
/B, II
CC-Link
(ID)
CC-Link
(RD)
CC-Link
(via G4)
PROSEC
T series
PROSEC
V series
• Serial communication module / computer link module
CPU series
Model CH1 CH2 AGOT SoftGOT
*4
Computer link modules / serial communication modules
*1
:Available :Not available
MELSEC-Q series
(Q mode)
MELSEC-QnA series
MELSEC-Q series
(A mode)
MELSEC-A series
Motion controller CPU
(A mode)
QJ71E71
QJ71E71-B2
QJ71E71-100
AJ71QE71
AJ71QE71-B5
AJ71QE71-B2
AJ71QE71N-B5T
AJ71QE71N-B2
A1SJ71QE71-B5
A1SJ71QE71N-B2
A1SJ71QE71N-B5T
AJ71E71-S3
AJ71E71N-B2
AJ71E71N-B5T
A1SJ71E71-B2-S3
A1SJ71E71-B5-S3
A1SJ71E71N-B2
A1SJ71E71N-B5T
• Ethernet module
CPU series
Model
Ethernet module
RS-422 RS-232C
SHARP
Link unit
YASKAWA Electric
Memory bus unit
Matsushita Electric Works PLC
HITACHI PLC
JW-21CM
JW-10CM
ZW-10CM
JAMSC-IF612
120 NOM 271 00
––
COMM-H
COMM-2H
––
JAMSC-IF60
JAMSC-IF61
120 CPU 341 00
CP-217IF
*10
AFP2462
AFP3462
AFP5462
COMM-H
COMM-2H
RS-422 RS-232C
Mitsubishi PLCs/motion controllers
Modules that can be connected with Mitsubishi PLC
Modules that can be connected to other manufacturer’s computer link module
Other manufacturers' PLCs/motion controllers
*9
RS-422 or RS-232 can be selected
RS-422 or RS-232 can be selected
RS-422 or RS-232 can be selected
RS-422 or RS-232 can be selected
CPU ModelSeries
Computer link connection
RS-422 RS-232 RS-422 RS-232
CPU direct connection
HITACHI PLC
(HIDIC H series)
Rockwell
Automation
PLC
(Allen-Bradley)
*12
SIEMENS AG
PLC
H-302 (CPU2-03H)
H-702 (CPU2-07H)
H-1002 (CPU2-10H)
H-302 (CPU-06H)
H-2002 (CPU2-20H)
H-4010 (CPU3-40H)
H-300 (CPU-03Ha)
H-700 (CPU-07Ha)
H-2000 (CPU-20Ha)
H-200
(
CPU-02H, CPE-02H
)
H-250 (CPU21-02H)
H-252 (CPU22-02H)
H-252B (CPU22-02HB)
H-252C
(CPU22-02HC, CPE22-02HC)
H-20DR
H-28DR
H-40DR
H-64DR
H-20DT
H-28DT
H-40DT
H-64DT
HL-40DR
HL-64DR
EH-CPU104
EH-CPU208
EH-CPU308
EH-CPU316
SLC500-20
SLC500-30
SLC500-40
SLC5/01
SLC5/02
SLC5/03
SLC5/04
SLC5/05
1761-L10BWA
1761-L10BWB
1761-L16AWA
1761-L16BWA
1761-L16BWB
1761-L16BBB
1761-L32AWA
1761-L32BWA
1761-L32BWB
1761-L32BBB
1761-L32AAA
1761-L20AWA-5A
1761-L20BWA-5A
1761-L20BWB-5A
1764-LSP
S7-300 series
S7-400 series
Large size
H series
H200~252
series
H series
board type
EH-150
series
SLC500
series
MicroLogix
1000 series
Digital CPU
MicroLogix
1000
series
Analogue CPU
MicroLogix
1500
series
*2
*2
*5
*6
*6
*6
*6
*6
*6
*6
*6
*6
*6
*6
*6
*3 *6
*3
*3
*3 *7
*3 *7
*1: Cannot be connected to the remote I/O stations regardless of connection configuration.
*2:
Including the case where MELSECNET/H is used as NET/10 mode. Cannot be connected to the remote I/O net mode.
*3:
The device range that can be monitored is the A3ACPU range. However, in the A3ACPU range, there is a device
range that cannot be monitored. For details, refer to the "GOT-A900 Series User's Manual Compatible Connection
System SH(NA)-080255-B".
*4: For the functions that use the calendar and clock data (e.g. alarm history function and time action function),
correct clock display and operation may not be performed.
*5: CC-Link (ID): CC-Link (Intelligent device station)
CC-Link (RD): CC-Link (Remote device station)
CC-Link (via G4): Connected to a CC-Link system via AJ65BT-G4-S3.
*6: In a multiple CPU system, CPU function version B or later should be used.
*7: Word specification (word device/word specification of bit device) cannot be written from the GOT to the CPUs
of software versions earlier than the followings.
A1NCPU/A2NCPU(-S1)/A3NCPU [with link]: Software version L
A1NCPU/A2NCPU(-S1)/A3NCPU [without link]: Software version H
A2CCPU/A2SCPU(-S1): Software version H
A0J2HCPU: Software version E
*8:
Cannot be used on the main base when a bus extension connector box is used. (Can be used on the extension base.)
*9: GOT should be connected to the A68RB extension base of hardware version B or later in the last stage of the
system. (Cannot be connected to the A3 RB main base.)
*10: The GOT cannot be connected when an extension base is used.
*11:
Only the Q series motion controller CPU where the peripheral software package SV13 or SV22 is installed can
be connected. The QCPU (Q mode) (CPU function version B or later) is also required. (Multiple CPU configuration)
When using the Q00CPU or Q01CPU (function version B or later), the following OS versions should be used.
*12: Available OS versions:
Q172CPU serial number: K******** and software package OS version: 00E or later
Q173CPU serial number: J******** and software package OS version: 00E or later
*13: Available OS versions:
Q172CPU serial number: N******** and software package OS version: 00H or later
Q173CPU serial number: M******** and software package OS version: 00H or later
*14: Available OS versions:
Peripheral software package OS version: 00H or later
*15: Use the A168B when using an extension base.
*16: Can be used only when GT SoftGOT2 is connected using the PC CPU unit. Use the PC CPU unit of PC setting
utility Ver 1.02 or later.
*17: For Q bus connection, use the QCPU with first 5 digits of serial No. of "03051" or later.
*18: Use the CPU of the following software version.
The CPU versions earlier than the followings version cannot be used.
A1NCPU/A2NCPU(-S1)/A3NCPU [with link]: Software version L or later
A1NCPU/A2NCPU(-S1)/A3NCPU [without link]: Software version H or later
A2CCPU: Software version H or later
A2SCPU(-S1): Software version C or later
A0J2HCPU: Software version E or later
*19: Refer to page 57 "Other manufactures' PLCs/motion controllers".
*20: Use the CPU function version B or later.
*21: Cannot be connected with Q00CPU, and Q01CPU via RS232 serial communication using the interface unit.
*9: Motion controller can be connected with only AGOT, but not with GT SoftGOT2.
*8: When using Ethernet module which supports data transmission speed of 100Mbps,
connect with GOT after converting the data transmission speed to 10Mbps using a hub.
*1: RS-485 communication is not possible; therefore, J2-C214-
S1 is not available.
*2:
With function version A, CH1 or CH2 can be connected. With
function version B or later, both CH1 and CH2 can be connected.
*3:
When connecting to A1SHCPU, A2SCPU(S1), A2HCPU(S1),
A1SJHCPU, A0J2HCPU, A171SHCPU(N), A172SHCPU(N),
use computer link module software version U or later version.
*4:
GOT2 can be connected via RS-232, but not via RS-422 communication.
*5: Only CH2 can be connected.
*6: Either CH1 or CH2 can be connected.
*7: Computer link module/serial communication module
operate within the range of An ACPU devices. (R device
cannot be recognized.)
*1, 2
*3, 4
*3
*3
*3
*1
*19
Computer link
connection
Ethernet
connection
*19
*19
*5 *5
*11
*11
*11
*11
*10
*12
*14
*12
*14
*13
*14
*13
*14
*13
*14
*13
*14
*15
*6
*17
*20
*1
*5
*6
*6
*6
*6
*9
*7
*7
*7
*7 *7 *7 *7
*18 *18 *18 *18
*18
*18
*18 *18
*18 *18
*18
*8
*21
*13
*13
*11
Application Q173CPU(N)
For transfer/assembly (SV13)
For automatic machine (SV22)
SW6RN-SV13QB
SW6RN-SV22QA
Q172CPU(N)
SW6RN-SV13QD
SW6RN-SV22QC
Version
00M or later
00M or later
Others
Connectable model list
Connectable model list
Connectable model list
AGOT
*8
SoftGOT
:Available :Not available