Specifications

P.30
~
Options
P.32
~
P.42
~
P.34
~
P.50
~
A975GOT
A970GOT
A970GOT
A960GOT
GT
Works2
A985GOT-V
A985GOT
A956WGOT
P.6
~
P.4
~
P.2
~
P.8
~
P.10
~
P.12
~
P.16
~
P.18
~
P.20
~
P.22
~
P.24
~
P.26
~
P.28
~
P.38
~
P.52
~
P.54
~
P.56
~
P.59
~
P.62
~
P.58
Concept Lineup
Special report
FA integrated functions
GT
SoftGOT2
Special report
New drawing software
Special report
Gateway functions
Features and
recommended points
A95 GOT
GOT
dictionary
Connection
configuration
Bus
connection
Specifications
External
dimensions
Function list
for each model
Connectable
model list
Notes
for use
List of
products
Sales &
service network
48 49
Max.3m
12"
10"
9"
7"
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A985(-V)
A97
A960
A956W
A956
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUS2SU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUS2S
A8GT-C EXSS
100 : 10m
200 : 20m
300 : 30m
A8GT-C EXSS-1 *4
100 : 10.6m
200 : 20.6m
300 : 30.6m
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
A8GT-C EXSS
100 : 10m
200 : 20m
300 : 30m
A8GT-C EXSS-1 *4
100 : 10.6m
200 : 20.6m
300 : 30.6m
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
50 : 5m
A8GT-C BS
100 : 10m
200 : 20m
300 : 30m
A8GT-C EXSS
100 : 10m
200 : 20m
300 : 30m
A8GT-C EXSS-1 *4
100 : 10.6m
200 : 20.6m
300 : 30.6m
A7GT-CNB
A1SC NB
05 : 0.5m
07 : 0.7m
30 : 3m
6" A956
A951 *3
A951 *3
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUS2SU
A9GT-BUS2SU
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUS2S
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
50 : 5m
A8GT-C BS
100 : 10m
200 : 20m
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A951 *3
A951 *3
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
A9GT-BUS2SU
A9GT-BUS2SU
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUS2S
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
50 : 5m
A8GT-C BS
100 : 10m
200 : 20m
300 : 30m
A9GT-BUS2SU
A9GT-BUS2SU
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUS2S
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
50 : 5m
A8GT-C BS
100 : 10m
200 : 20m
300 : 30m
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A951
0m
3m
33m30m
1 unit
Within 33m
More than 3m,
Within 30m
Within 3m
2 units
Within 3m
3 units
Within 3m
More than 3m
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
Max.30m
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
Max.30m
Max.33m
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
*2 *2 *2 *2
*5
*7
*5
*5
*5
*7
*5
*1
*1
*1
*6
*1
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A951 *3
Max.30m
Max.3m
Max.33m
Max.30m
Max.3m
Max.33m
Max.30m
Cable 1
Cable 0 Cable 1
Cable 1
Cable 1
Cable 1 Cable 2 Cable 3
Cable 2
Cable 2
GOT1
GOT1
GOT1
GOT1
GOT1 GOT2 GOT3
GOT2
GOT2
Bus connector conversion box
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
Max.3m
*1
Cable 1
GOT1
PLC
Notes for bus connection
Make sure to power on the PLC CPU and GOT as instructed below.
When multiple GOTs are connected, they may be powered on in any sequence.
<For the Q/QnA/ACPU/A series motion controller (Except the Q4ARCPU)>
(a) Switch the power on of the PLC CPU and GOT simultaneously.
(b) Switch the power on of the PLC CPU first, then GOT.
When multiple GOTs are connected, the PLC CPU starts to run when all the GOTs
powers are switched on.
<For the Q4ARCPU>
Power on the GOT first. Then, switch the power on of the Q4ARCPU redundancy
system after 1 or 2 seconds.
When multiple GOTs are connected, switch the power on of all GOTs first. Then,
power on the Q4ARCPU redundancy system after 1 or 2 seconds.
For bus connection, the PLC power unit supplies the amount of current equivalent to
that consumed by the connected GOTs.
When calculating the current consumption, make sure to include the current to be
consumed by the GOTs. Note that the current consumption must not exceed the
amount of the current supplied by the PLC power supply unit. The following shows
the current consumed by one GOT.
•When connected to the QCPU (Q mode): 255mA per GOT
•When connected to other than QCPU (Q mode): 220mA per GOT
Only Q CPU (Q mode) supports bus connection, but Q CPU (A mode) does not.
GOT is recognized as an intelligent communication module by QCPU (Q mode),
requiring 16 I/O points. GOT cannot be connected anywhere between the base unit
and extension base unit.
GOT should be connected to the last of the extension base units and be included
within the maximum allowable number of extension base units.
In addition, GOT needs to be assigned to I/O slots of the last extension base unit,
but not to the base unit.
It occupies one full extension base (16 points X 10 slots), thus cannot share the
same extension base unit with others. However, it can be shared with other GOTs.
Although GOT is usually connected to the last of extension base unit, it is assigned
as the second from the last when extension base QA1S6 B is used, with QA1S6 B
being the last extension base unit. (See the diagram below.)
If 10 slots cannot be left open for GOT, the number of slots can be reduced by
using GX Developer.
Up to 5 GOTs can be connected.
GOT is recognized as an intelligent communication module by QnA/ACPU/A series
motion controller, requiring 32 I/O points. GOT cannot be connected anywhere
between the base unit and extension base unit.
GOT should be connected to the last of the extension bases and be included within
the maximum allowable number of extension base units. In addition, GOT needs to
be assigned to one slot of the extension base, but not to the base unit. The extension
base unit cannot share with I/O module, special function module, or the kind.
<For Q4A(R)CPU, Q3ACPU, A3 CPU, A4UCPU>
When maximum number of the extension base units (7 base units) is connected,
vacant slots are necessary.
<For A0J2HCPU>
GOT is assigned as follows:
Number of extension base units: 1, I/O slots: 0 to 3
<Others>
GOT can be connected within the range of I/O points even if maximum extension
base units (2 or 3) are installed and there is not vacant slot.
i.e. ACPU (small type) Number of extension base units: 2, I/O slots: 0
*4: The special function unit with the following model is shown.
AJ71QC24(R2/R4)
*5: The special function unit with the following models are shown.
AD51(S3), AD51H(S3), AD51FD(S3), AD57G(S3), AJ71C21(S1), AJ71C22(S1), AJ71C23, AJ71C24(S3/S6/S8), AJ71E71(-S3),
AJ71UC24, A1SJ71C24(-R2/PRF/R4), A1SJ71UC24(-R2/PRF/R4), A1SJ71E71-B2/B5(-S3), AJ61BT11, A1SJ61BT11
Restrictions on the number of GOTs that can be connected
Notes for when power is switched on
Notes for system configuration
Restrictions on the number of GOTs that can be connected depends on the PLC CPU and the number of special function module to be installed.
Number of GOTs that can be connected
GOT + number of special function
units to be installed
Up to 3 units
No limit when GOT + special function units as shown in
*4
Up to 6 units when GOT special function units as shown in
*5
Up to 3 units
Up to 6 units when GOT special
function units as shown in *5
Up to 2 units
Up to 2 units when GOT special
function units as shown in *5
Number of GOTs that can be connected
GOT + number of special function
units to be installed
Up to 1 units
Up to 2 units when GOT special
function units as shown in *5
Up to 3 units
Up to 6 units when GOT special
function units as shown in *5
Up to 2 units
Up to 2 units when GOT special
function units as shown in *5
QnA(R), QnAS(H)CPU
AnU, AnA, A2US, A2USHCPU CPUs not shown on the left
A0J2HCPU
A series Motion controller
A173UH(-S1), A273U, A273UH(-S3), A373U(-S3)CPU
A series Motion controller
CPUs not shown on the left
When using Q CPU (Q mode)
When using QnA/ACPU/A series motion controller
Q38B
main base unit
Q68B
extension base unit
QA1S6B
extension base unit
GOT
Level of extension base unit
Connection method
231
*1: When using extension base unit(s), make sure that the total length of the main cable and
extension cables (between base units) is within 3m.
*2: (Example) A cable of 0.7m for A1SC B is A1SC07B.
*3: No communication interface is required.
*4: Use the value of the A8GT-C EXSS to calculate the cable length of the A8GT-C EXSS-1.
*5: Use the A168B extension base unit.
*6: Only the A173UHCPU(-S1) is applicable.
*7: When using extension base unit(s), make sure that the extension cable length (between
base units) is within 3m, and the total length of all cables is within 33m.
Bus connection
Bus connection
Bus connection
When connected with A series motion controller CPU (small type)
When using the A13UHCPU(-S1), up to 3 GOTs can be connected.
When using other CPUs, up to 2 GOTs can be connected.
Refer to “Connectable model list” on page 56.
Bus connector
conversion box
Cable 0
GOT connection conditions
Installation distance
of the first unit
from base unit
Number
of GOTs
System configuration
Component details
Cable 1 Cable 2 Cable 3
GOT3
Communication interface
Unit typeBoard type
Model name
Size
GOT main unit
GOT2
Communication interface
Unit typeBoard type
Model name
Size
GOT main unit
GOT1
Communication interface
Unit typeBoard type
Model name
Size
GOT main unit
Connection distance
Others