Specifications

P.30
~
Options
P.32
~
P.42
~
P.34
~
P.50
~
A975GOT
A970GOT
A970GOT
A960GOT
GT
Works2
A985GOT-V
A985GOT
A956WGOT
P.6
~
P.4
~
P.2
~
P.8
~
P.10
~
P.12
~
P.16
~
P.18
~
P.20
~
P.22
~
P.24
~
P.26
~
P.28
~
P.38
~
P.52
~
P.54
~
P.56
~
P.59
~
P.62
~
P.58
Concept Lineup
Special report
FA integrated functions
GT
SoftGOT2
Special report
New drawing software
Special report
Gateway functions
Features and
recommended points
A95 GOT
GOT
dictionary
Connection
configuration
Bus
connection
Specifications
External
dimensions
Function list
for each model
Connectable
model list
Notes
for use
List of
products
Sales &
service network
44 45
Up to 3 GOTs can be connected.
For connectable CPU modules, refer to Connectable mode list on page 56.
Max.5m
Max.5m
12"
10"
9"
7"
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A985(-V)
A97
A960
A956W
A956
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUS2SU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUS2S
A8GT-C EXSS
100 : 10m
200 : 20m
300 : 30m
A8GT-C EXSS-1 *4
100 : 10.6m
200 : 20.6m
300 : 30.6m
A1SC B
0.7 : 0.7m
12 : 1.2m
30 : 3m
50 : 5m
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
50 : 5m
A8GT-C EXSS
100 : 10m
200 : 20m
300 : 30m
A8GT-C EXSS-1 *4
100 : 10.6m
200 : 20.6m
300 : 30.6m
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
50 : 5m
A8GT-C BS
100 : 10m
200 : 20m
300 : 30m
A8GT-C EXSS
100 : 10m
200 : 20m
300 : 30m
A8GT-C EXSS-1 *4
100 : 10.6m
200 : 20.6m
300 : 30.6m
A7GT-CNB
A1SC NB
05 : 0.5m
07 : 0.7m
30 : 3m
50 : 5m
6" A956
A951 *3
A951 *3
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUS2SU
A9GT-BUS2SU
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUS2S
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
50 : 5m
A8GT-C BS
100 : 10m
200 : 20m
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A951 *3
A951 *3
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
50 : 5m
A9GT-BUS2SU
A9GT-BUS2SU
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUS2S
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
50 : 5m
A8GT-C BS
100 : 10m
200 : 20m
300 : 30m
A9GT-BUS2SU
A9GT-BUS2SU
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUS2S
A1SC B
07 : 0.7m
12 : 1.2m
30 : 3m
50 : 5m
A8GT-C BS
100 : 10m
200 : 20m
300 : 30m
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A951
Bus connector
conversion box
Cable 0
0m
5m
35m30m
1 unit
Within 35m
More than 5m,
Within 30m
Within 5m
2 units
Within 5m
3 units Within 5m
More than 5m
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
Single GOT can be connected.
12"
10"
9"
7"
A985(-V)
A97
A960
A956W
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-J2C B
10:1m
A0J2-PW
A0J2C
03: 0.3m
(for horizontal
installation)
06: 0.55m
(for vertical
installation)
10: 1m
(for extension)
20: 2m
(for extension)
6" A956
A951 *3
Power supply unit
0m
1m
Within 1m1 unit
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
Max.30m
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
Max.35m
Max.30m
Max.35m
Max.5m
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
Max.1m
Max.35m
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
*2 *2
*2*2 *5
*2 *2
*7
*6
*7
*6
12"
10"
9"
7"
6"
A985(-V)
A97
A960
A956W
A956
A9GT-BUSS
A9GT-BUS2S
A9GT-50WBUSS
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A9GT-BUSSU
A9GT-BUS2SU
A951 *3
Max.30m
Max.30m
Max.30m
Cable 1
Cable 0 Cable 1
Cable 1
Cable 1
Cable 1
Cable 0
Cable 1
Cable 2 Cable 3
Cable 2
Cable 2
GOT1
GOT1
GOT1
GOT1
GOT1
GOT1
GOT2 GOT3
GOT2
GOT2
Bus connector conversion box
A1SP60A1S62P A1SP60 A1SP60 A1SH42 A1SH42A2USCPU
RUNPOWER
ERROR
L.CLR
RESET
RUN
STOP
RESET
Max.5m
*1
Cable 1
GOT1
PLC
PLC
Power supply unit
*5
When connected with QnACPU (small type) or ACPU (small type)
When connected with A0J2HCPU
*6
Bus connection
Bus connection
Bus connection
GOT connection conditions
Installation distance
of the first unit
from base unit
Number
of GOTs
System configuration
Component details
Cable 1 Cable 2 Cable 3
GOT3
Communication interface
Unit typeBoard type
Model name
Size
GOT main unit
GOT2
Communication interface
Unit typeBoard type
Model name
Size
GOT main unit
GOT1
Communication interface
Unit typeBoard type
Model name
Size
GOT main unit
Connection distance
Cable 0
GOT connection conditions
Installation distance
of the first unit
from base unit
Number
of GOTs
System configuration
Component details
Cable 1
GOT1
Communication interface
Unit typeBoard type
Model name
Size
GOT main unit
Connection distance
*1: When extension base units are used, the total cable distance between main and
extension units should be within 6 m.
*2: Cable model name (example) A1SC B 07: 0.7m, i.e. Model name: A1SC07B
*3: No communication interface is required.
*4: Use the value of the A8GT-C EXSS to calculate the cable length of the A8GT-C EXSS-1.
*5: The power source unit is required for connecting GOT.
*6: When extension base units are used, the extension cable distance between main and
extension units should be within 6 m.
*7: When extension bases are used, the extension cable length (between bases) should
be within 6m. In this case, the total length of all cables should be within 36m.
Others