Specifications
P.30
~
Options
P.32
~
P.42
~
P.34
~
P.50
~
A975GOT
A970GOT
A970GOT
A960GOT
GT
Works2
A985GOT-V
A985GOT
A956WGOT
P.6
~
P.4
~
P.2
~
P.8
~
P.10
~
P.12
~
P.16
~
P.18
~
P.20
~
P.22
~
P.24
~
P.26
~
P.28
~
P.38
~
P.52
~
P.54
~
P.56
~
P.59
~
P.62
~
P.58
Concept Lineup
Special report
FA integrated functions
GT
SoftGOT2
Special report
New drawing software
Special report
Gateway functions
Features and
recommended points
A95 GOT
GOT
dictionary
Connection
configuration
Bus
connection
Specifications
External
dimensions
Function list
for each model
Connectable
model list
Notes
for use
List of
products
Sales &
service network
36 37
The GOT-A900 series screen can be simulated on a personal
computer to debug the screen. If the screen needs to be modified as
a result of debugging, it can be done using drawing software (GT
Designer2) and the results can be checked immediately with the GT
Simulator2, so debugging efficiency can be greatly improved.
Refer to GT Simulator2 in Product overview on page 31 for details.
•Data can be displayed as lists.
•
Five elements can be displayed on a single line. (Up to 128 lines)
•
Data is sorted and displayed in the order of device values to
be monitored. Data can be displayed in either the
descending order tool using frequency, or failure frequency.
Data
list
Display
condition
specification
Display
switching
A variety
of touch
switches
Simulation
debugging
Device
monitor
System
monitor
Status
monitor
•
If a combination of ON/OFF conditions for two devices is valid, it is reported
to an external unit or PLC CPU. Audio output, bit ON/OFF, bit inversion,
momentary, or data set (fixed value/indirect value) can be selected.
•All screens and an individual screen can be used at the same time.
•It is effective as background processing for
display conditions, write conditions, or report
print conditions.
B0 B1 B10 B11
B100
K
MIVP 10 W100
The servo monitor and parameter setting of the Q series motion controller
(Q172CPU(N), Q173CPU(N)) can be performed on the GOT screen.
Parameter setting/monitoring is enabled for up to 3 Q172CPU(N)s or
Q173CPU(N)s on the base.
Time delay switch function
ON delay:This switch works when it is kept pressed for a specified period of time. This
protection function prevents a switch from being activated when it is touched by mistake.
OFF delay:This touch switch continues output for a specified period of time after the
switch is released.(The time can be set from 1 to 5 seconds.)
Operating condition (trigger) specification
(interlock function)
Operation protection can be set easily for the touch switch or numeric
input function by specifying operating conditions.
•Works when a bit device is specified (ON/OFF).
•Works when a word device is within a specified range.
Documentation
assistance
Offset specification
An offset (index qualification) can be specified by writing a word for a touch switch.
Write device: D100
Offset device: W0
If W0 is 0, data is set at D100.
If W0 is 1, data is set at D101.
Supporting MELSECNET/10, (II)/B
•Since the line status of each MELSECNET is displayed clearly,
the communication status can be easily checked.
•Details on lines and information about local and remote stations is
provided from various points of view.
•This function can be disabled by setting a password.
•The A956W/A95 GOTdisplays a window screen.
•The MELSECNET/H cannot use this feature.
[Function list]
Motion monitor
•Current value monitor •Positioning monitor •SFC error history •Servo monitor
•Error list •Current value history monitor •Error list (axis specification)
Parameter setting
•Servo parameters (basic parameters, adjustment parameters)
•Monitoring of current value history is not supported by the A95 GOT.
•
Servo amplifier version B1 or later supports servo parameter setting for the MR-J2S.
•
In a multiple CPU system, Q series CPU needs to be used as PLC No.1.
Also, Q series PLC CPU should be mounted to the left of the
Q172CPU(N) or Q173CPU(N) on the base unit.
•JOG operation, servo test, etc. are not supported.
Refer to Notes for Use on page 58 for the Q series motion controller
CPU versions.
•Continuous trigger : The display is always updated.
•Periodical trigger : A display interval can be specified (in seconds).
•Edge trigger : ON/OFF display
It can be displayed when a specified device is turned on or off.
It can be displayed forcibly when the screen is switched.
•Level trigger : ON/OFF display
It is always displayed when a specified device is ON or OFF.
Whether to retain or clear the display can be specified when a trigger is invalid.
•
Switching by bit (2 combinations) The display is switched when a monitor device is ON or OFF.
•Switching by word (63 combinations)
Display color, etc. can be specified by setting a range of values using
a comparison equation (inequality).
A constant or word device can be specified for a comparison term.
Indirect
specification
(offset device)
•Since several data items can be displayed or input in one
location, a setting can be input to multiple devices.
•An offset device can be set for each object.
PLC station
number
switching
•
The PLC station number can be switched and a remote station can be monitored on a screen, so the screen
does not need to be changed for each PLC station number. (Effective during transient communication.)
•
Since the station number is switched by changing the station number device
value, it can be done easily with a touch switch or a sequence program.
Screen
call
•Since the common parts of several screens can be created and
displayed as a separate screen, screen data can be reduced.
•
Several screens being used can be changed by modifying the call screen only.
•
Downloading time can be reduced by transferring screens one at a time.
•There is no limit to the number of screens that can be called.
List
program
edit
Note 1) unavailable for Q/QnA/motion controller/computer link connection.
A sequence program cannot be read with dedicated instructions specified.
Note 2) The photo shows this function used with ladder monitor. (On the A956W/A95 GOT,
this function cannot be used with ladder monitor.)
Touch switch area specification
•The area of touch switch can be set 16-dot interval, so wrong input of
an adjacent touch switches can be avoided.
Previous screen switch function
To use the previous screen switch function, a screen switch (switch
target: upper layer) works as a previous screen switch when its internal
device of GS450.b14 is set ON.
PC card is necessary when the power is switched ON again, otherwise
the previous screen switch function is lost.
Drawing software
(including GT Simulator2)
Maintenance functions
(when MELSEC Q/QnA/A/FX CPU or motion controller or Servo amplifier is connected)
Started from GT Simulator2. A list of devices being used on the screen
currently displayed by GT Simulator are displayed.
Since GOT internal devices (GB, GD, GS) can also be monitored,
debugging efficiency can be further improved.
MELSECNET/10 control station details
*1
Network
monitor
*1
Motion
monitor
Connecting GOT to servo amplifier in a pulse train output system,
parameter setting, error history, and diagnosis functions can be used
on the GOT. Without having a programming software, servo amplifiers
can be monitored and set from on-site GOT.
Refer to Special report 2 on page 9 for details.
Servo
amplifier
monitor
*1
*2: The AD75M parameter is monitored in the small range AD75P parameter.
•
List programs are displayed in the window of the ladder monitor, and on the base screen of the monitor screen.
•
The keyword set for the sequence program is checked, and if it is correct, lists can be edited to assure security.
•Lists can be displayed in English.
•The list program edit screen can be hard copied and stored as history.
Special
module
monitor
*1: Supported by the A95 GOT-M3 among the A95 GOTs.
*2: GT Designer is included in SW D5C-GOTR-PACK(E)(V).
SW3NIW-A8GOTP is not included in GT Designer2/GT Works2.
Ladder
monitor
PLC
(Multi PLC system)
GOT
PULL
USB
Q02HCPU
MODE
RUN
ERR
USER
BAT
BOOT
RS-232
PULL
POWER
Q61P-A1
USB
Q172CPU
MODE
RUN
ERR
USER
BAT
BOOT
RS-232
PULL
CN2
CN1
FRONT
SSCNET
USB
Q172CPU
MODE
RUN
ERR
USER
BAT
BOOT
RS-232
PULL
CN2
CN1
FRONT
SSCNET
USB
Q172CPU
MODE
RUN
ERR
USER
BAT
BOOT
RS-232
PULL
CN2
CN1
FRONT
SSCNET
SY. ENC1
SY. ENC1
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Q172Q172
Q172EX
SY. ENC TREN
QX40
1
2
1
2
*1
System alarm
•PLC CPU or network connection errors or GOT errors are displayed by
only specifying a display area.
•Predefined error messages are displayed.
•Module configuration is automatically determined and a menu is
displayed. Information of special module such as I/O information and
buffer memory values can be displayed on the GOT, and special X/Y
and buffer memory data can be modified.
•It is not necessary to create a screen for I/O check and special
function module maintenance.
•It can be used to start a
machine or check special
function module operation.
•It can be read from the user
screen and used freely as a
screen library.
•This function can be disabled by setting a password.
PLC program can be monitored in ladder format. (Either one or Q, QnA,
A, FX ladder is shown) A95 GOT does not support the ladder monitor.
A956WGOT does not support QnA/A/FX ladder monitor. (Q ladder
monitor only)
•Setting and changing of device values/timer/counter.
•Searching includes device search, step searching, contact, coils, etc.
•Device comments of GX Developer are displayed.
•The cause of problems can be investigated easily by the fault cause
search function. (QnA ladder monitor does not support.)
This easily finds corresponding coils by
touching contacts.
QnA/A/FX does not support touch search.
(Q ladder monitor only)
This function is unavailable for instructions
other than contacts and
coils and word devices.
The Cause fault search
and touch search cannot
be used simultaneously.
Return to screens in
reverse order of switching.
Base screen 20
Base screen 16
Base screen 33
Base screen 16
Base screen 8
Screen switching
Previous screen switch
*1: The front screen switch allows to return up to nine previous screens.
*2: This function can be applied only to base screens.
*3: Previous screen switch cannot be saved to PC card.
GT Designer2 is compatible with GT Designer.
Source data Source data
Data created on FX-PCS-DU/WIN
GX Developer device comment read*3
BMP format data
DXF format data
Monitor data of GP series
GT Converter is required
(included in GT Designer2)
(Upload from GOT)
GT Converter is required
(included in GT Designer2)
Used software
New drawing software for GOT900 series
GT Designer2
SW D5C-GTD2-J(V)/E
SW D5C-GTWK2-J(V)/E
Drawing software for GOT900 series
GT Designer
SW D5C-GOTR-PACK(E)(V)
*3: GX Developer's device comment helps device setting while creating screens.
Data created by GT Designer2
Data created by GT Designer
GT Designer panel kit read*4
Monitor data of GOT800 series
Monitor data of A77GOT(-S )
Monitor data of A64GOT
Monitor data of AD57G-S3
*4: The panel kit of GT Designer can be used as a parts library.
Model
name
Product
name
Model
name
Product
name
Used software
Data
conversion
*2
Compatibility with other software data
Compatibility with GT Designer
New
Function description
GOT Dictionary
GOT Dictionary
GOT Dictionary
Advanced features increase your satisfaction!
Example of setting 5 elements
<Data set example> <Bit momentary example>
1-second
1-second
ReleasePress
When the
signal is ON
<OFF delay operation>
ReleasePress
When the
signal is ON
<ON delay operation>
1-second
delay
Invalid operation
Not output
Invalid operation
(Trigger: MO/ON)
(Touch switch input state)
(Momentary output: YO)
•Since device values (including timer/counter settings) can be
monitored and changed easily, a seperate device check maintenance
screen does not need to be created.
•You can toggle between decimal and hexadecimal display, between
16-bit and 32-bit display, and comment display.
•Different PLC devices can be displayed on 4 windows at the same
time. The registration monitor, batch monitor, timer/counter monitor,
and BM (buffer memory) monitor can be displayed and changed
(including timer/counter settings) together with each window.
•This function can be disabled by setting a password.
•The A956W/A95 (W)GOT displays a window screen.
The device value/bit set/bit RST can
be changed by a single operation.
Quick test display
( )
A memory
board is
required
A memory
board is
required
A memory
board is
required
A memory
board is
required
A memory
board is
required
A memory
board is
required
[Special function modules that can be monitored]
A series module
<Positioning modules>
For large modules:AD75
*2
, AD70, AD70D, AD71, AD72
For small modules:A1SD75, A1SD70, A1SD71
<Analog modules>
For large modules:A68AD, A68ADN, A616AD,
A616TD, A68RD, A62DA-S1, A616DAV,
A616DAI, A84AD
For small modules:A1S64AD, A1S62DA,
A1S62RD, A1S63ADA, A1S68DAV, A1S68DAI,
A1S68AD
<Others>
For large modules:Input module, output
module, AD61, A61LS, A62LS-S5,
AJ71PT32-S3 (32/48 points), AJ71ID1-R4,
AJ71ID2-R4
For small modules:Input module, output
module, A1SD61, A1SJ71PT32-S3 (32/48
points), A1SJ71ID1-R4, A1SJ71ID2-R4,
A1S64TCTT-S1, A1S64TCTTBW-S1,
A1S64TCRT-S1, A1S64TCRTBW-S1
Q series unit
<Positioning modules>
QD75M , QD75P , QD75D
Input module
Output module
<Analog modules>
Q64AD, Q68ADV, Q68ADI,
Q62DA, Q64DA, Q62E, Q62D
Sequence programs can be edited as lists. (The key layout and operation
are the same as for the A8UPU.)
Applications
Minor changes can be made to programs
in the field. Sequence programs can be
edited easily without using peripheral
equipment. The customer who used to
ship a machine with the A8UPU
(programming unit) can reduce costs.
Functions and operations
List: 4-line display
Applicable PLCs: MELSEC-A series
Program edit: Editing is possible when the PLC stops.
Use GOT utility screen or touch switch
function to switch between screens.
Screen captures for documentation
•Screen images are printed to several formats.
•Screen images are copied to a BMP and TEXT formats. This allow
uses to finish complete operating manuals or documentations in
short time.
: Compatible : GT Converter is required : Not compatible
: Compatible : GT Converter is required : Not compatible
New drawing software for GOT900 series
GT Designer2
SW D5C-GTD2-J(V)/E
SW D5C-GTWK2-J(V)/E
Drawing software for GOT900 series
GT Designer
SW D5C-GOTR-PACK(E)(V)
Key window for
device specification
Cause search
result screen
Ladder
monitor
Menu Each station data link
GT Converter is required
(included in GT Designer2)
Conversion on GT Converter (included in GT
Designer2 and GT Works2) is necessary after
SW3NIW-A8GOTP(included in optional software,
SW D5C-GOTR-Pack(E)(V)) conversion is done.
GT Converter is required
(included in GT Designer2)
Conversion on GT Converter (included in GT Designer2
and GT Works2) is necessary after SW3NIW-A8GOTP
drawing software for GOT 800 series (included in GT
Designer2 and GT Works2) conversion is done.