Specifications
Gravimetric Batch Blenders w/Mitsubishi Control Chapter 6: Troubleshooting  73 
Problem  Corrective action 
Check the blender’s scale calibration and verify that the batch 
hopper is not overfilling. If the hopper is overfilling, adjust your 
batch size. If this is correct, then you are probably not accounting 
for material scrap or other items in your process. 
Recorded Inventory Totals 
don’t match what I’ve actually 
used 
Some error can be introduced by not weighing every batch. Check 
the Recipe Page. 
Max Hopper Weight Exceeded 
Alarm continues to re-occur. 
Stop the Blender and the Start it again. This causes the blender to 
perform an automatic feeder calibration. If this doesn’t fix it, then 
manually perform feeder calibrations and retest. 
Check that the printer is a SERIAL printer. If not, then you will 
need to either get a SERIAL printer or purchase a SERIAL to 
PARALLEL converter. 
Printer did not print 
Check printer communication settings under Panel View Config. 
Check the blender’s Alarm Log to determine if the blender was 
powered up during the print time. The blender keeps track of 
Power On and Off conditions. 
I’m missing an Automatic 
Inventory Report 
Check that the date and time are set correctly on the Panel View 
Config Page. 
The blender intermittently dumps a batch of material with one or 
more of the components incomplete. 
Check the recipe information; ensure that both the percentages and 
batch size are set properly. 
Check the status of the alarm flags & Feeder Setup to ensure that 
all of the feeders are set to Retry. In addition, if the blender is 
configured for timed batches then this can cause error. 
Blender occasionally dumps an 
incorrect batch. 
Check supply hopper ventilation to prevent problem associated 
with leaky vacuum receiver flappers. 
Check the mixer high-level switch sensitivity. When the sensor is 
covered by material, the indicator lamp on the back of the switch 
should be lit. To adjust the sensitivity, use the small adjustment 
screwdriver that was provided with the blender. The adjustment 
pot is located on the back of the sensor. Rotate clockwise to 
increase the sensitivity (less material in front of the switch to 
actuate it). Rotate counter clockwise to decrease the sensitivity 
(more material covering the switch). 
Blender keeps dumping after 
mixer is full. 
Check the mixer high-level sensor connection to the control panel. 
Check the mixer high-level switch sensitivity. Fines may have 
coated the level switch; it needs readjustment. 
Check the proximity switch connection. 
Make sure that the recipe is correct. 
Blender will not batch with 
empty mixer. 
Check batch size. 