Specifications
Gravimetric Batch Blenders w/Mitsubishi Control  Chapter 4: Operation  58 
4-2  Controller Description & Operation 
Display Description (LCD) 
The Slide Gate/Auger blending system utilizes a standardized menu format. Each screen 
was designed to be user-friendly and provide the operator with the necessary information to 
run the blender. 
A typical menu is shown in the figure above. This display, which is defaulted to when the 
controller is turned on, provides the operator with the following information and options: 
•  The ability to change Recipe Values 
•  Accept a newly entered Recipe 
•  Start or Stop the blender 
•  Access to the Recipe Book 
•  Access to the Clean-out Screen 
•  Access to the Inventory Screen 
•  Access to the Controller Setup Screen 
Note:  Please refer to the Slide Gate/Auger menu structure shown on the next page. 
The menu tree shows the structure for a standard Slide Gate/Auger blender. 
When the unit is initially installed the Manual Control menu will be used. This screen is 
primarily used for trouble shooting the blender. All outputs can be controlled manually and 
all digital inputs from the proximity switches can be viewed. Pressing the “Manual Control” 
key when in the “Setup” menu accesses this screen. To gain access to the “Setup” menu, a 
password will be requested. 
Empty Entire 
Blende
r
Test Alarm 
Output 
Current Hopper 
Weight 
Warning Message 
Open or Close 
Feede
r
Open or Close 
Weigh Hopper
Start or Stop 
Mixer Moto
r
Open or Close 
Mixer Knife 
Gate 
Go back to 
Setup Directory 
Low Level 
Prox Status