User`s manual

Graphic Operation Terminal F930GOT Additional Functions (V 2.20/3.00 or later) 15
15-5
Cable 6ES7901-1BF00-0XA0 manufactured by Siemens is available also.
15.3.2 Support device range list
Word devices are shaded, and bit devices are not shaded.
*1 Notation used in the GOT
The device specification method is partially different. Refer to the next paragraph.
15.3.3 Device specification method and restraint in GOT
Device specification method
Specify devices in the following formats.
1) Bit device
¨¨¨¨
In "
", specify the device symbol (shown in Table 1) in one alphabet.
•In "
¨¨¨¨
", specify the device No. (shown in Table 1) of the specified device in a deci-
mal value in three or four digits.
•In "
", specify the bit position. The available range is from 0 to 7.
Example: When specifying "M01205"
Device symbol = M
Device (byte) No. = 120
Bit position = 5
2) Timer (T) and counter (C)
The specification method is equivalent to that for bit devices except that the bit position (
)
is omitted.
Example: When specifying "T250"
Device symbol = T
Device No. = 250
Table 15.7: Support device range list
Device name (symbol)
Available setting range
Notation in PLC
Notation in GOT
*1
Input relay (I) I0.0 to I511.7
Output relay (Q) Q0.0 to Q511.7
Bit memory (M) M0.0 to M2047.7
Timer current value (T) T0 to T511
Counter current value (C) C0 to C511
Data register (D)
DB1.DBW0 to DB1.DBW65534
DB2.DBW0 to DB2.DBW65534
DB1023.DBW0 to DB1023.DBW65534
D000100000 to D000165534
D000200000 to D000265534
D102300000 to D102365534
GOT side
D-sub
(female),
9-pin
connector
HMI adapter
side (PLC side)
D-sub
(female),
9-pin
connector
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
CD(DCD)
RD(RXD)
SD(TXD)
ER(DTR)
SG(GND)
DR(DSR)
RS(RTS)
CS(CTS)