User`s manual

Graphic Operation Terminal F930GOT Introduction 1
1-13
1.8 Connection of MELSEC FX/A Series (CPU PORT)
Connect the GOT to the programming connector in the PLC, and perform communication.
This communication method is easy because sequence programs, setting and interface are
not required once the connected PLC is set in the operation environment setting (on the SET-
UP MODE screen).
Use the following cables in connection of the PLC.
1) Connection of the FX
1
/FX
2
/FX
2C
/A Series
2) Connection of the FX
0
/FX
0S
/FX
0N
/FX
2N
/FX
2NC
Series
* If the screen mode is selected while cables are not connected, a communication error occurs.
Table 1.3:
Series name
FX
0
/FX
0S
/FX
0N
/FX
2N
/FX
2NC
/FX/FX
2C
Series
CPU PORT (RS422)
(In 1:N connection, select "CPU PORT (RS232C)"
for the second and fourth GOTs.)
FX
2N
(when FX
2N
-232-BD is used)
CPU PORT (RS232C)
(In 1:N connection, select "CPU PORT (RS422)"
for the second and fourth GOTs.)
AnN, AnA, AnS, AnSJ, AnSH, A1SJH, A2C, A2CJ,
A0J2H, AnU, AnUS, A2USH, A1FXCPU
CPU PORT (RS422)
(In 1:N connection, select "CPU PORT (RS232C)"
for the second and fourth GOTs.)
Motion controller
A171SCPU-S3
A171SHCPU
A172SHCPU
A272UHCPU
CPU PORT (RS422)
(In 1:N connection, select "CPU PORT (RS232C)"
for the second and fourth GOTs.)
OUT
I N
OUT
CPU¥E
PROG¥E
5
4
3
2
1
0
7
6
5
4
3
2
1
0
X7
X6
X5
X4
X3
X2
X1
X0
COM
N
L
Y5
Y4
Y3
Y2
COM2
Y1
COM1
Y0
COM0
COM
24+
RUN
POWER
F930GOT
FX-40DU-CAB (3 m),
FX-40DU-CAB-10M (10 m),
FX-40DU-CAB-20M (20 m) or
FX-40DU-CAB-30M (30 m)
FX-50DU-CAB0 (3 m),
FX-50DU-CAB0-1M (1 m),
FX-50DU-CAB0-10M (10 m),
FX-50DU-CAB0-20M (20 m) or
FX-50DU-CAB0-30M (30 m)
FX/FX
2C
Series PLC
A Series PLC
AnN, AnA, AnS, AnSJ, AnSH, A1SJH, A2C,
A2CJ, A0J2H, AnU, AnUS, A2USH, A1FX, CPU
FX
0
/FX
0S
/FX
0N
/FX
2N
/FX
2NC
Series PLC
Motion controller
A171SCPU-S3, A171SHCPU, A172SHCPU,
A272UHCPU
1) 2)