User`s manual
Graphic Operation Terminal F930GOT Additional Functions (in V.2.00 or later) 13
13-19
Operation example 2: When two or more storing devices are specified, the write opera-
tion FM0V or BM0V is available.
FM0V: A fixed value added by the current value of an indirect device is written to two
or more storing devices.
Storing devices: D10 to D12 (16-bit) (3 points)
Indirect device: D100
Fixed value: 20
* When the current value of D100 is "30", "50 (= 20 + 30)" is written to D10 to D12.
BM0V: A fixed value added by the current value of an indirect device is written to two
or more storing devices.
Different from FM0V, the number of indirect devices is equivalent to that of
storing devices. Indirect devices correspond to storing devices on the one-to-
one basis.
Storing devices: D10 to D12 (16-bit) (3 points)
Indirect devices: D100 to D102
Fixed value: 20
Fixed value Indirect device Write 16-bit storing word devices: D10 to D12
20 + D100
→
D10
20 + D101
→
D11
20 + D102
→
D12
* When the current value of D100 to D102 are "30", "40" and "50" respectively,
the following values are written to D10 to D12.
20 + 30 = 50 (D10)
20 + 40 = 60 (D11)
20 + 50 = 70 (D12)
Fixed value Indirect device Write 16-bit storing word devices: D10 to D12
20 + D100 D10
D11
D12