User`s manual

Graphic Operation Terminal F930GOT Creation of Display Screens (FX-PCS-DU/WIN-E) 9
9-39
u
uu
u
Display example
"RUN" or "STOP" are displayed as the "Ascii" objects using three data registers D100 to
D102.
When X0 becomes ON, "NORMAL" is displayed.
When X1 becomes ON, "HIGH!!" is displayed.
- "Ascii" object
Character Size: W:
×
2, H:
×
2
Word Device: D100
Data Length: 3
-Display
- Sequence program
n
nn
n
Important point
The "Ascii" object displays specified texts on one screen as shown above. Accordingly, the
screen is not required to be changed over or to be overlaid.
TEMP.HIGH
LINE 1
TEMP.NORMAL
LINE 1
"Text" object
"Ascii" object
Text (display color)
Bg (background color)
(The broken line is not
actually displayed.)
When X0 becomes ON When X1 becomes ON
*"LINE 1" is displayed as the "Text" object.
X0
MOV
MOV
MOV
H 4F4E
H 4D52
H 4C41
D100
D101
D102
FNC12
FNC12
FNC12
X1
MOV
MOV
MOV
H 4948
H 4847
H 2121
D100
D101
D102
FNC12
FNC12
FNC12
4F
4D
4C
4E
52
41
D100
D101
D102
(H)
(H)
(H)
Upper Lower
Storage status of data registers
49
48
21
48
47
21
D100
D101
D102
(H)
(H)
(H)
Upper Lower
Storage status of data registers