User`s manual

Graphic Operation Terminal F930GOT Creation of Display Screens 8
8-29
Devices assigned for system information execute the following operations.
When M10 becomes ON from OFF, the alarm history is
cleared.
When M11 becomes ON, the backlight of the display screen
becomes extinguished after a specified time.
D11 stores the recipe No.
The screen Nos. of screens
currently displayed are stored in
D20 to D22.
User screens Nos. 0 to 499
and system screens No. 1000
and later are available.
When screen overlay is not
performed, "0" is stored in
D21 and D22.
D20 to D22
D23 stores the ID No. of an object.
M10
M11
D20
D21
D22
The screen Nos. of
screens currently
displayed are written to
them.
3
4
5
The ID No. of a manipulated
object is stored in D23.
GOT Sequence program
Read devices
Write devices
Always ON
K1M10D10MOV
D11K
¡
MOV
Always ON
K1M20D24MOV
M20 remains ON while an alarm device remains ON.
M23 become ON when the backup battery power of the GOT
has dropped.
M22 becomes ON when change of numeric data is
completed.
M20
M22
M23
M12 to M13 is not used
(unusable).
ID
When read devices
Write devices
D10 (b0 to b1 are developed to M10 to M12.)
D11
D20 to D24 (b0 to b3 are developed to M20 to M23.)
:
:
D23
are assigned.