Specifications

4M41 ENGINE -
Vacuum Pump
11B-17-2
INSPECTION
VACUUM PUMP ASSEMBLY
(1) Connect a vacuum tank (capacity: 10 liters) to the vacuum
pump assembly
5
through a vacuum gauge
A
.
B
: Engine oil inlet
C
: Engine oil outlet (to oil pan)
(2) With the engine running, read the engine speed when
the vacuum builds up to the standard value.
Standard value:
Degree of vacuum: 93 kPa or more
Pump speed: 1500 r/min
(3) If the reading deviates from the specified standard value,
replace the vacuum pump.
PWEE9409-D
E
Feb. 2000Mitsubishi Motors Corporation Added
B
A
C
D
5