Service manual
Table Of Contents
\0
\0
I
E
C1J
....
'"
~
Qj
::s
~
k
0
~
k
"
>
0
a
Slip torque
of
gear
complete
Fit
of
governor sleeve
on
governor shaft
Fit
of
governor sleeve
groove
on
sliding piece
Fit
of
floating lever
on
bolt
6 (0.236)
Fit
of
floating lever
on
pin
Fit
of
shackle
on
pin
Fit
of
shackle
on
bushing
8 (0.315)
Fit
of
control lever shaft
in bearing bushing
Fit
of
adaptor
capsule
on
5(0.197)
adaptor
Mechanical governor
Adjusting sequence
Item
1
High-speed
control
2
Ungleich
control
3
Low-speed
control
4
Adaptation
to engine
5
Stop
lever
operation
Unit:
mm
(in.)
0.4
~0.6
kg-m
Adjust by means
of
(2.9
~4.3
Ib-ft)
shim.
0.006
~0.059
[0.15
I
[(0.00024
~0.00232)1
(0.0059)
[
0.03~0.\3
I
(0.0012
~0.0051)
[0.18
J
(0.0071 )
Replace sliding piece.
-
Replace floating lever
or bolt.
[ 0.01
~0.052
) Replace floating lever
(0.00039
~0.00205)
[ 0.08 I
or pin.
(0.0031 )
Replace shackle or
shackle pin.
[ 0.01
~0.055
I
(0.00039
~
0.00217)
Replace shackle or bushing.
I 0.025
~0.07
I
(0.00098
~
0.00276)
I 0.2 I
(0.008)
Replace shaft or bushing.
[ 0.02
~0.\3
I
I
0.18 I
Adaptor should slide
(0.0008
~0.0051)
(0.0071) smoothly
in
a:-dal
direction.
Adjusting lever angle
Pump rpm
Control
rack position RW. mm (in.)
4°
±5°
1150
8.3
~8.7
(0.327
~0.343)
1400
3.3-3.9
(0.130~0.154)
1300
5.9
~6.9
(0.232
~0.272)
4°
±5°
350
9.7
~9.6
(0.382
~0.378)
600
8.7
~9.3
(0.343
~0.366)
700
8.4
~9.0
(0.331
~0.354)
_16°
±
5°
300
5.5
~6.1
(0.217
~0.240)
400
4.1
~5.5
(0.161
~0.217)
100
14.8 (0.583),
max
Adjusting lever angle
Pump
rpm
Injection
quantity
mm
3
(cu in.)/rev./cyl.
4°
±5°
600
36.5 ± 1.5 (0.00223 ± 0.00009)
(by full-load
stopper)
1150
36 ± 1.5 (0.00220 ±
0.00009)
(by
torque
spring)
1400
6 ± 1 (0.00037 ±
0.00006)
(by lever)
RW
shall be
not
more
than
2
mm
(0.08 in.)
when
stop
lever
is
operated
with
adjusting lever
VH
placed in low-speed
control
position.