OC246-37
4. How to check the parts PL12AK/PL18AK/PL24AK/PL30AK/PL36AK/PL42AK
Parts name Check points
Disconnect the connector then measure the resistance using a tester.
(Surrounding temperature 50-F~86-F)
Measure the resistance between the terminals using a tester.
(Surrounding temperature 68-F~86-F)
Measure the resistance between the terminals using a tester.
(Surrounding temperature 68-F~86-F)
Measure the resistance between the terminals using a tester.
(Surrounding temperature 50-F~86-F)
Vane motor
Drain pump
Drain sensor
(Refer to the thermistor)
(Refer to the thermistor)
Room temperature
thermistor (RT1)
Liquid pipe
thermistor (RT2)
1
2
Yellow
Yellow
1
2
3
Normal
4.3k"~9.6k"
Abnormal
Open or short
Abnormal
Open or short
Normal
0.6k"~6.0k"
NormalConnector Abnormal
300" Open or short
Normal Abnormal
101" Open or short
Orange
Red
White
Red Ñ Yellow
Red Ñ Blue
Red Ñ Orange
Red Ñ White
Blue
Yellow
35
1
2
4
Measure the resistance between the terminals using a tester.
Fan motor
1
1
2
2
3
3
Red
White
Black
Relay connector
Protector
12/18AK
21.7"
26.5"
Abnormal
Open or short
24/36/42AK
8.5"
12.2"
Red-Black
White-Black
Motor terminal
or
Relay connector
Normal
PL