Specifications

Using programmable controllers System configuration
2 - 2
2.2 System configuration
2.2.1 System configuration example
The following system configuration is explained as an example.
Inputs and outputs are configured as switches and lamps respectively.
LS30001
Fig. 2-2: Example of a system configuration
NOTE Wires to the power supply module and the power of the external I/O devices are omitted.
No. Name Model Description
Power supply module L61P Supplies power to modules such as CPU module.
CPU module L02CPU
Integrates the control of the programmable control-
ler.
END cover L6EC
Supplied with the CPU module. Be sure to connect an
END cover on the right of the terminal module.
DIN rail
(IEC 60715)
TH35-7.5Fe
TH35-7.5Al
TH35-15Fe
The programmable controller system is secured by
attaching it to the DIN rail.
DIN rail stopper
Use DIN rail stoppers that can be attached to the DIN
rails.
Connection cable
(USB cable)
MR-J3USBCBL3M
(USB A type - USB mini B
type)
Connects the personal computer with GX Works2
installed and the CPU module.
External power supply
Supplies power to the external I/O devices. Use the CE
marked models and be sure to perform grounding for
the FG terminal.
Tab. 2-2: Description of items in fig. 2-2