Specifications
31
Dec. 2012
Mitsubishi IPM-series Application Note
(2) The circuit current of control power supply of IPM
The circuit current of control power supply of IPM is shown below.
This current is average of DC and fc=20kHz.
Condition : VD=15V,Tj=25{C, Unit : mA
AC220V
IPM L-series 䌎-side P-side(1 phase)
DC 20kHz DC 20kHz
Type. Name Typ Max Typ Max Typ Max Typ Max
PM 50RLA/RLB060 2 0 3 0 2 5 3 4 5 1 0 7 1 0
PM 50CLA/CLB060 1 5 2 5 2 1 2 9 5 1 0 7 1 0
PM 75RLA/RLB060 2 0 3 0 3 4 4 6 5 1 0 1 0 1 4
PM 75CLA/CLB060 1 5 2 5 2 8 3 8 5 1 0 1 0 1 4
PM100RLA060 2 0 3 0 3 8 5 2 5 1 0 1 1 1 5
PM100CLA060 1 5 2 5 3 2 4 4 5 1 0 1 1 1 5
PM150RLA060 2 0 3 0 5 2 7 1 5 1 0 1 5 2 1
PM150CLA060 1 5 2 5 3 5 4 8 5 1 0 1 5 2 1
PM200RLA060 2 4 3 4 6 0 8 1 6 1 2 2 0 2 7
PM200CLA060 1 8 2 8 5 8 7 9 6 1 2 2 0 2 7
PM300RLA060 2 4 3 4 8 3 1 1 3 6 1 2 2 5 3 4
PM300CLA060 *) 1 8 2 8 8 0 1 0 8 6 1 2 2 5 3 4
PM450CLA060 *) 1 1 1 8 4 5 6 1 1 1 1 8 4 5 6 1
PM600CLA060 *) 2 0 2 7 5 5 7 5 2 0 2 7 5 5 7 5
*) The value per device
AC440V
IPM L-series 䌎-side P-side(1 phase)
DC 20kHz DC 20kHz
Type. Name Typ Max Typ Max Typ Max Typ Max
PM25RLA/RLB120 2 0 3 0 2 4 3 3 5 1 0 7 1 0
PM25CLA/CLB120 1 5 2 5 1 9 2 6 5 1 0 7 1 0
PM50RLA/RLB120 2 0 3 0 3 4 4 6 5 1 0 1 0 1 4
PM50CLA/CLB120 1 5 2 5 3 0 4 1 5 1 0 1 0 1 4
PM75RLA/RLB120 2 0 3 0 4 2 5 7 5 1 0 1 3 1 8
PM75CLA/CLB120 1 5 2 5 3 5 4 8 5 1 0 1 3 1 8
PM100RLA120 2 4 3 4 5 3 7 2 6 1 2 1 7 2 3
PM100CLA120 1 8 2 8 5 1 6 9 6 1 2 1 7 2 3
PM150RLA120 2 4 3 4 7 6 1 0 3 6 1 2 2 3 3 2
PM150CLA120 1 8 2 8 6 7 9 1 6 1 2 2 3 3 2
PM200CLA120 1 1 1 8 4 0 5 4 1 1 1 8 4 0 5 4
PM300CLA120 2 0 2 7 5 5 7 5 2 0 2 7 5 5 7 5
PM450CLA120 2 0 2 7 5 5 7 5 2 0 2 7 5 5 7 5
*) The value per device
Using IPM