11. Installing the grille
A
11.1. Checking the contents
• This kit contains this manual and the following parts.
Accessory name Q’ty Remark
1 Grille 1 760 × 760 (mm)
2 Screw with captive washer 4 M5 × 0.8 × 25
3 Gauge 1 (Divided into four parts)
4
Stick for the intake grille open/close
1 ø8 × 750
(PLP-2.5KB only)
5 Tapping screw 2 4 × 10
6
Hook for temporary placement
2—
A Auto vane
1
4 5
6
ø20
2 3
11.2. Preparing to attach the grille
• With the gauge 3 supplied with this kit, adjust and check the position-
ing of the unit relative to the ceiling. If the unit is not properly posi-
tioned relative to the ceiling, it may allow air leaks or cause condensa-
tion to collect.
• Make sure that the opening in the ceiling is within the following toler-
ances:
690 × 690 - 710 × 710
• Make sure that step A is performed within 52-57 mm. Damage could
result by failing to adhere to this range.
A Main unit
B Ceiling
C Gauge 3 (inserted into the unit)
D Ceiling opening dimensions
A
D
C
B
A=54
+3
–2