Specifications
Dual-element Indicators
Mechanical Indicators
95
Specifications
Size (width
✕
height) mm
Model name
Operation principle
Accuracy (grade)
Scale length (mm)
Weight (kg)
Indicator rating (DC)
110✕110 wide-angle indicator
LM-11NE
Movable coil
1.5
175
1.0
Approximate internal resistance value (Ω)
1200
50
25
15
1mA side: 1200, 5mA side: 50
5mA side: 50, 10mA side: 25
10mA side: 25, 1mA side: 1200
Delivery period
Both elements have
same ratings
Respective elements
have different ratings
1mA
5mA
10mA
4 - 20mA
1/5mA
5/10mA
10/1mA
Standard
product
Immediate delivery
Quasi-standard
product
Within 20 days
Special
product
21 to 60 days
Symbol
Reference delivery period
Delivery period classification
LM-11NE
Remarks
(1) Indication accuracy: 15% of full scale
(2) Relative deviation between the two needles: 2.0% of full scale
(3) Withstand voltage
Between electrical circuit as a whole and outer casing: 2210VAC, 5s
Mutually between input circuits (indicator alone): 50V AC, 1min
(4) In the case of a double scale, each scale is drawn in the same color as the
corresponding needle.
(5) In the case of an electrical quantity scale (A, V, W, var, cosf, Hz), the AC/DC symbol
and 3-phase circuit symbol of the scale (primary side) are not indicated. The symbol
of the receiving indicator is indicated.
(6) Please make sure to read the “Safety Precautions” (pp.5-8) and the “Selection
Precautions” (p.9) to assist in selecting the model and use specifications suited to the
application.
Note 1. For low-voltage circuits, grounding of the secondary side of the instrument voltage transformer is unnecessary.
(In the case of separate scales)
LM-11NE 0-100A B
0-9000V/0-150kV
(Different rating)
FS1mA
Special specifications
Colored lines, colored
bands, etc.
FS10/1mA
5
Model name
Scale
Cover type
Indicator rating
The items in must be specified.
Number of
units
BB
RR
V
6600/110V
6.6kV
T-51KAV voltage
transducer
150V AC/1mA DC
110000/110V
110kV
150V AC/1mA DC
VT
Note 1
VT
Note 1
T-51KAV voltage
transducer
V
Usage example
Two measured quantities are indicated by the same indicator.
Two independent movable coil indicators are incorporated, and by combination with a detector and a
transmitter, two measured quantities, such as voltage and current, water level and water quantity, power
and reactive power can be indicated by the same indicator to enable reduction in panel space. The
indicator can be combined with power transducers to enable measurement of various electrical quantities.
The needle colors are black and red (the front side needle as viewed from the front face of the indicator is
black and the rear side needle is red).
f104
4545
4545
Panel hole opening
dimensions (mm)
4-M5 mounting screws
4—f6
9419
15
10.3
17.3
M5 red needle input terminal screw
Upper black needle
adjust button
Lower red needle
zero adjust button
f100
M5 black pointer input
terminal screw
110
110
Outer dimensions
BB
RR
Power transducer
(2)
Red needle input
Black needle input
Input (2)
Input (1)
Power transducer
(1)
Connection diagram
Specifications of LM-11NE dual element AC
voltmeter
Scales 0 to 9kV (black)
0 to 150kV (red)
The zero point numeral is in black.
Scale divisions: The positions of 6.6kV and 110kV
are the same.
Indicator internal resistance: 1.2kΩ (for both
elements)
Ordering method