Specifications

Indicators with Maximum and Minimum Needles
Mechanical Indicators
89
Specifications
Size (width height) mm
DC ammeter
110110
LM-11ZNDA
LM-11YNDA
Movable coil
1.5 (marker needle: 2)
175
AC ammeter
110110
LM-11ZNAA
LM-11YNAA
DC voltmeter
110110
LM-11ZNAV
LM-11YNAV
Receiving indicator
110110
LM-11ZNRI
LM-11YNRI
Movable coil
1.5 (marker needle: 2)
175
5, 10, 15
20mA
40Ω (20mA)
1, 3, 5
10, 15A
300mV
15A
or more
300mV
Manual and electromagnetic marker needle reset (electromagnetic marker needle reset voltage: 100-110VAC/DC ±10%); consumption VA: 6VA
With maximum needle
With maximum and minimum needles
Model name
Indicator rating
Operation principle
Accuracy (grade)
Scale length (mm)
Marker needle reset
Frequency
Weight (kg)
Rated voltage or
rated current
Consumption VA
Response time
Accessory
Delivery period classification
Rectifier
1.5 (marker needle: 2)
175
50 or 60Hz
3.2
1, 5, 10, 15, 20, 30A
1VA
0.1s
T-150
50 or 60Hz
3.2
100, 110, 150, 190
259, 300V
5VA
0.1s
T-150
3.2
DC 5mA
DC4-20mA
650
Ω
(DC5mA), 100
Ω
(DC4-20mA)
0.3s
3.2
0.3s
Standard
product
Immediate delivery
Quasi-standard
product
Within 20 days
Special
product
21 to 60 days
Symbol
Reference delivery period
Delivery period classification
Note 1
Outer dimensions
4-M5 mounting screws
Minimum value marker needle (green) (only for LM-11YN)
Driving needle (black)
Maximum value marker needle (red)
Zero adjust button
Manual marker needle
reset button
M5 terminal screw for electromagnetic
marker needle reset
M5 input terminal screw
Panel hole opening dimensions (mm)
4—f6
f104
153
f100
1517.3
22.7
110
110
45
45
45
45
Model name
Model name
Indicator rating
Scale
Cover type
Special specifications
Special specifications
LM-11ZNAA
LM-11YNRI
5A 0-300A
Indicator ratingScale
FS5mA0-1200kW
CT ratio or VT ratio
300/5A B
Cover type
B
Frequency
50Hz
The items in must be specified.
AC ammeter/AC voltmeter
Receiving indicator
Colored lines, colored
bands, etc.
Double scale, colored
lines, etc.
Number of
units
Number of
units
2
2
These indicators have marker needles indicating the maximum and minimum
values. The response time of these indicators is extremely fast.
The needle response time is 0.1s (0.3s for DC input).
The maximum value marker needle, minimum value marker needle and
driving needle are red, green and black, respectively.
Using the indicators in combination allows the marker needles to be reset to
the driving needle both manually and electromagnetically.
LM-11ZNAA LM-11YNAV
Note 1.
Models with a rating exceeding 15ADC are provided with an externally mounted 300mV shunt.
Additionally, in ordering, please specify the resistance value so that the lead wire round trip resistance value is 0.8Ω or less.
Remarks
(1) Refer to p.90 and p.92 if an AC voltmeter is to be used as a ground voltmeter.
(2) The T-150 rectifier is a dedicated accessory (non-compatible accessory) and thus cannot be used in
combinations besides those specified for the indicators. The distance between the indicator and the
T-150 rectifier must be 5m or less or the round trip lead wire resistance must be 0.5
Ω
or less.
(3) Set the duration of supplying electricity to the electromagnetic marker needle resetting terminal to
within 5s. Additionally, use a switch that “opens” when released.
(4) The overload capacity is 2 times the rated current for 2s.
(5) For an AC ammeter or AC voltmeter, please specify the frequency.
(6) An expanded scale cannot be manufactured for an AC ammeter.
(7) Do not use with a circuit through which an inrush current or other current that exceeds the rating flows.
(8)
Please make sure to read the “Safety Precautions” (pp.5-8) and the “Selection Precautions” (p.9) to assist in selecting the model and use specifications suited to the application.
Ordering method